38
| ENGLISH
PROBLEM
The pump does not switch on
Message
Cause
Intervention
COM ERROR
The communication between the
control card and the voltage card is
suspended
If the message persists the the electronic cards could be
damaged
LOW LEVEL
Signal of level not present with Entry
Signal of level activated
Verify the presence of water in suction or the functioning
of the level signal
EXT OFF
Put out of service through an external
signal with external Signal Entrance
active
Put back into service via the external signal
None
Breakdown of the pressure sensor
Verify the reading on the display with a reference
manometer, re-programme or substitute the pressure
sensor
PROBLEM
Pump always functioning, even if not required
Message
Cause
Intervention
None
Leaks in the plant greater than 2 l/min
Find the leaks and block them
None
Breakdown or obstruction of the load
sensor
Inspect and clean the load sensor
PROBLEM
The pump stops too soon, even if there is a demand
Message
Cause
Intervention
None
Fault of the flow sensor sensor
Verify the functioning of the flow sensor
PROBLEM
Performance of the pump below that rated
Message
Cause
Intervention
None
Presence of air in the intake manifold
Clean out the intake manifold
None
Pump obstructed or damaged
Inspect the pump and eliminate the problem
Содержание TISSEL-100
Страница 2: ......
Страница 77: ...77 30 5 TISSEL 100 TISSEL 100 OFF ON...
Страница 80: ...80 30 TISSEL 100 TISSEL 100 10 Qmax 80 V 80 x 10 8 70 Pset 4 4 x 70 2 8 TISSEL 100 230 50...
Страница 83: ...83 BASIC P 2P A RO ADV d MF LF HF Td PF TPF TP TF RF FS US EI i...
Страница 84: ...84 EO AI AT W V Pd iDRY FM FLAT SET F INSP WH TH NS SH E1 E1H E2 E2H E3 E3H E4 E4H EE TEST...
Страница 92: ...92 OVERTEMP MODULE COM ERROR LOW LEVEL EXT OFF 2 Prestazioni della pompa inferiori a quelle di targa...
Страница 94: ......