32
| ENGLISH
SETTING THE ADVANCED PARAMETERS (ADV)
The following is the list of the
ADVANCED PARAMETERS
which improve the functioning and which require a detailed knowledge
of the system
ADV
DISPLAY
PARAMETERS
DESCRIPTION
u.m. Default Min
Max
Step
d 0.40
DIFFERENTIAL
RESTART PRESSURE
Sets the differential between the pressure
selected (SET PRESSURE) and the effective
restart pressure
bar
0.5
0.4
1.0
0.1
psi
6
6
15
1.5
MF 50
NOMINAL
FREQUENCY OF THE
MOTOR
Sets the nominal frequency of the motor.
The set value must be the same as that of
the nameplate of the motor
Hz
50
50
60
-
LF 30
MINIMUM
FUNCTIONAL
FREQUENCY
Sets the minimum functional frequency
Hz
30
25
40
1
HF 50
MAXIMUM
FUNCTIONAL
FREQUENCY
Sets the maximum functional frequency.
ATTENTION: the increase in the maximum
frequency compared to the nominal
frequency can cause strong overloads of
the motor.
Hz
MF
MF-5 MF-3
1
Td 10
DELAYED STOP
CAUSED BY DRY
RUNNING
Sets the delayed stop of the pump in
conditions of dry running.
ATTENTION: too high values of a delayed
stop can damage the pump
sec
10
1
100
1
PF .50
MINIMUM POWER
FACTOR
Sets the minimum value of the power
factor below which the inverter stops the
pump to stop it running dry.
In order to define the minimum value of
the power factor read the value with the
inflow completely closed and
as a margin subtract 3 points.
-
0.50
0.50
0.99
0.01
TPF 0
RETARDED STOP
CAUSED BY POWER
FACTOR
Sets the delay in stopping the pump in
conditions of a power factor below the
minimum one. The delay must be as short
as possible as the pump must never run
when dry.
Setting the value at “0” one excludes the
control of dry running with COSFI
sec
0
0
3
1
TP10
INTERVALS BETWEEN
RESTARTS CAUSED BY
DRY WORKING
Sets the interval between two successive
automatic attempts to restart after a stop
due to dry working.
Setting the value to”0” one excludes
automatic attempts to restart
min
10
0
100
1
TF 3
RETARDED STOP
DUE TO NO FLOW
Sets the delay in stopping the pump in
conditions of no flow
sec
3
1
15
1
Follows
i
Содержание TISSEL-100
Страница 2: ......
Страница 77: ...77 30 5 TISSEL 100 TISSEL 100 OFF ON...
Страница 80: ...80 30 TISSEL 100 TISSEL 100 10 Qmax 80 V 80 x 10 8 70 Pset 4 4 x 70 2 8 TISSEL 100 230 50...
Страница 83: ...83 BASIC P 2P A RO ADV d MF LF HF Td PF TPF TP TF RF FS US EI i...
Страница 84: ...84 EO AI AT W V Pd iDRY FM FLAT SET F INSP WH TH NS SH E1 E1H E2 E2H E3 E3H E4 E4H EE TEST...
Страница 92: ...92 OVERTEMP MODULE COM ERROR LOW LEVEL EXT OFF 2 Prestazioni della pompa inferiori a quelle di targa...
Страница 94: ......
Страница 95: ......