ELECTRONIC PUMP CONTROLLER

PRESFLO

®

 is a device that 

starts and stops the pump to 

which it is fi tted, thus replacing 

traditional pressure switch / 

surge tank systems.

The pump is started when, as 

a tap is turned on, the pressure 

within the system drops below 

the “start-up pressure” (Pm), 

and is stopped when the fl ow 

USER’S MANUAL

rate required is zero or less 

than the “shut-off fl ow rate” 

(Qa). 

PRESFLO

®

’s electronics protect 

the pump against unsuitable 

operating conditions such as 

dry running or repeated start-

ups due to leaks.

Technical specifi cations

Operating conditions

A. Compatible/non compat-

ible fl uids 

PRESFLO

®

 is suitable for use 

with clean water and chemical-

ly non-aggressive liquids. If the 

fl uid contains impurities, a fi lter 

should be fi tted upstream.

B. Environmental conditions

PRESFLO

®

 should not be used 

where there is the risk of an 

explosion. The temperature 

of the location should range 

between 0°C and 40°C, and 

the humidity should not exceed 

90%.

C. Power supply

Make sure that the variation 

in the power supply is never 

more or less than 10 % of the 

RATING value. 

Higher values may cause 

damage to the electronic 

components.

PRESFLO

®

 can only be used 

with single-phase pumps.

Working area

Flow rate

Pressure

Shut-off fl ow rate

Start-up pressure

2

  l/min (0,5 gpm)

Red =

Blue =

Yellow = 

Qa

Pm

Safety regulations 

Before installing or using 

PRESFLO

®

, read this manual 

carefully and thoroughly.

The pump should be installed 

and serviced by qualifi ed per-

sonnel, responsible for making 

the hydraulic and electrical 

connections in compliance with 

the relevant regulations.

PEDROLLO S.p.A. shall not 

be held liable for any damage 

relating to, or resulting from, an 

improper use of the product, 

or for any damage relating to, 

or resulting from, servicing or 

repairs carried out by unqual-

ifi ed personnel and/or with 

non-OEM spare parts. 

The warranty, which is valid 

for 24 months from the date 

of purchase, will no longer be 

applicable should the product 

suffer damage as a conse-

quence of the use of non-OEM 

spare parts, tampering or 

improper use. 

When starting the installation, 

check the following:

- the power supply is switched 

off.

- the power lines can withstand 

the maximum current.

- the cable bushings and circuit 

board cover have been properly 

assembled and secured ( see 

Electrical Connections ).

- Power supply network must 

be fi tted with proper protection 

device (fuse or magne-

to-thermal relay) upstream of 

PRESFLO

®

When servicing the product, 

check the following:

- the system is not pressurised 

(turn a tap on)

- the power supply is switched 

off.

Emergency Stop

When in use, the pump can 

be stopped in the event of an 

emergency: 

press STOP/RESTART.  

PRESFLO

®

 is put STAND-BY.

Never disassemble

water accumulator

Water accumulator

Losses

- Voltage: ~230 Volt / ~115 Volt 

- Frequency: 50-60 Hz

- Current: 10A, max 12A for 3 sec.

- Current: 12A, max 16A for 3 sec.

- Protection grade: IP 65

- Start-up pressure (Pm): 0,8/1,5/2,2 bar 

   (12/22/32 psi)

- Shut-off fl ow rate (Qa): 2 litres/min (0,5 gpm)

- Connections: 1” BSP / 1” NPT 

- Maximum working pressure: 10 bar (145 psi)

- Bursting pressure: 40 bar (580 psi)

- Weight: 650 g

- Protection against: 

  - dry running (automatic restart) 

  - repeated start-ups

- Max room temperature: 40°C

- Max liquid temperature: 55°C

- Type of drive: 1C

- Max manual operations on 

  push button: 1000

- Max automatic operations 

  on relay: 100000

- Class 3A PTI

- Pollution degree : 2

- Max rated voltage pulse: 2,5 kV

- 230V 12A for EMC test

- Pressure operating  

  differential: 10 bar

Before installing

the product, check that 

the RATINGS correspond 

with those required.

2,2

 bar (32 psi)

1,5

 bar (22 psi)

0,8

 bar (12 psi)

Содержание PRESFLO 50066/115

Страница 1: ...i PEDROLLO S p A declina ogni responsabilit per danni derivanti da uso improprio del prodotto e non responsabile di danni causati da manuten zioni o riparazioni eseguite da personale non qualificato e...

Страница 2: ...anto idrauli co e fa partire la pompa si accende il led verde Pump On Se entro 15 secondi dall avvia mento PRESFLO non rileva il corretto adescamento arresta la pompa per anomalia di marcia a secco At...

Страница 3: ...ALE pompa in fase di arresto La pompa stata fermata manual mente Vi rimane fino a nuovo comando BREVE pressione nessuna conseguenza LUNGA pressione ripristino del FUNZIONAMENTO NORMALE della pompa Ved...

Страница 4: ...che difettose Controllare le connessioni elettriche tra PRESFLO e pompa PRESFLO in FUORI SERVIZIO Rimettere PRESFLO in servizio vedere Paragrafo Utente funzionamento punto 3 PRESFLO in arresto tempora...

Страница 5: ...t regulations PEDROLLO S p A shall not be held liable for any damage relating to or resulting from an improper use of the product or for any damage relating to or resulting from servicing or repairs c...

Страница 6: ...and indicates a dry running error message Attention When the pump is started for the first time it may have to be run for longer in order to com plete the priming procedure Press the STOP RESTART but...

Страница 7: ...topped and put in STAND BY To reset see point 3 If the absence of flow lasts for a few seconds the pump is stopped STAND BY NORMAL SERVICE pump during shutdown See NOTE 1 PRESFLO has detected that the...

Страница 8: ...uate start up pressure Pm for the chosen application Relocate PRESFLO to another position Install a model with a higher start up pressure Pm Faulty electrical connections or pump out of service Check...

Страница 9: ...les PEDROLLO S p A declina toda responsabilidad por da os derivados del uso impropio del producto y no ser responsable por los da os causados por mantenimiento o reparaciones ejecutadas por personal n...

Страница 10: ...l encendido PRESFLO no detecta el cebado correcto detiene la bomba por anomal a de marcha en seco Atenci n A la primera puesta en marcha puede que sea necesario hacer funcionar la bomba m s tiempo par...

Страница 11: ...condici n hasta que se ejecute un mando BREVE presi n ninguna consecuencia LARGA presi n restablecimiento del FUNCIONAMIENTO NORMAL de la bomba V anse los puntos 2a 2b FUNCIONAMIENTO NORMAL bomba en...

Страница 12: ...FLO Instalar un modelo con presi n de marcha Pm mayor Conexiones el ctricas defectuosas o bomba no funcionante Controlar las conexiones el ctricas y el funciona miento de la bomba PRESFLO en FUERA DE...

Страница 13: ...e d g ts provoqu s par un usage impropre de l appareil ou un entretien ou des r parations effectu s par un personnel non qualifi et ou avec des pi ces de rechange non d origine L utilisation de pi ces...

Страница 14: ...LO ne d tecte pas un amor age dans les 15 secondes du d marrage il arr te la pompe pour fonction nement sec Attention S il s agit de la premi re mise en route de la pompe faire fonctionner la pompe pe...

Страница 15: ...ommande successive BREVE pression aucun effet LONGUE pression r tablissement du FONCTIONNEMENT NORMAL de la pompe Cf points 2a 2b FONCTIONNEMENT NORMAL pompe en cours d arr t HORS SERVICE cf REMARQUE...

Страница 16: ...FLO Installer une version avec une pression d exercice Pm sup rieure Connexions lectriques ou pompe d fectueuses V rifier les branchements lectriques et le fonction nement de la pompe PRESFLO HORS SER...

Страница 17: ...l sse vorschriftsm ig hergestellt werden PEDROLLO S p A haftet nicht f r Sch den die infolge von durch unqualifiziertes Personal ausgef hrten Wartungs oder Reparaturarbeiten und oder durch Verwendung...

Страница 18: ...tellt h lt er die Pumpe wegen Trockenlauf Anomalie an Achtung Bei der ersten Inbetriebsetzung kann es notwendig sein die Pumpe l ngere Zeit funktionieren zu lassen damit sie vollkommen gef llt wird Di...

Страница 19: ...einem erneuten Befehl in diesem Zustand KURZES Dr cken keine Konsequenz LANGES Dr cken Wiederherstellung des NORMALEN BETRIEBS der Pumpe Siehe Punkte 2a 2b NORMALER BETRIEB Pumpe beim Herunterfahren...

Страница 20: ...es PRESFLO ver ndern Ein Modell mit h herem Betriebsdruck Pm installieren Elektroanschl sse defekt Die Elektroanschl sse zwischen PRESFLO und Pumpe kontrollieren PRESFLO AUSSER BETRIEB Den PRESFLO wie...

Страница 21: ...6 A 1 5 Bar SN 15060002 RU EN FR DE IT ES A PRESFLO B PRESFLO 0 C 40 C 90 C 10 PRESFLO 2 Qa Pm PRESFLO PEDROLLO S p A 24 PRESFLO STOP RESTART PRESFLO PRESFLO Pm Qa PRESFLO 2 2 32 psi 1 5 22 psi 0 8 12...

Страница 22: ...LO Pm PRESFLO 15 50 ft PRESFLO 1 5 22 psi Pm 2 2 32 psi 1 15 psi Pm PRESFLO PRESFLO PRESFLO POWER ON PRESFLO PUMP ON 15 PRESFLO STOP RESTART IP 65 1 Pm 15 PRESFLO PRESFLO 1 15 30 60 PRESFLO 2 1 2 PRES...

Страница 23: ...1 2a 2c 2b 3 4a 4b PRESFLO PRESFLO PRESFLO Pm 3 Pm PRESFLO Pm 3 2a 2b 1 PRESFLO 2a 2b 3 PRESFLO 3 2 PRESFLO 2a 2b 3 PRESFLO 30...

Страница 24: ...6136311 Fax 39 045 7614663 e mail sales pedrollo com www pedrollo com 1 2 3 4 5 6 OR PRESFLO San Bonifacio 30 08 19 PEDROLLO S p A Il Presidente Silvano Pedrollo 2014 35 2011 65 RoHS 2012 19 2003 108...

Отзывы: