6.2
Bidirectional Data Transmission
For bidirectional data transmission the message traffic occurring
between CAN busses A and B is to be forwarded via the WLAN
network. For this two PCAN-Wireless Gateways are needed, where
for each one, a Send and Receive route must be created.
In this example Gateway 1’s IP address is 192.168.1.201 and it is
connected via CAN channel 1 to CAN bus A. Gateway 2’s IP address
is 192.168.1.202 and it is connected via CAN channel 2 to
CAN bus B.
The difference here, when compared with the example in chapter
6.1, is solely that the opposite message forwarding from CAN bus B
to CAN bus A must also be realized.
The Routes on Gateway 1:
Incoming messages from Gateway 1 are to be transferred into the
WLAN network. For this, a Send route with the following values
must be created.