background image

 

1

Ver. 3.3 

VproX  1000-M 

1000  KEYS/TAGS  SYSTEM  -  MULTIENTRANCES

 

DESCRIPTION 

VproX 1000 is an advanced access control system based around the individual unique Videx Coded Contact Key or 
Proximity Key giving over 4 billion combinations. System can handle up to 30 main doors ( 4 doors included on board ) 
and up to 100 apartment doors. All additional main doors and apartment doors need a local unit VproX 1000-A 
(connected to the VproX 1000 system by 3 wires BUS shielded, for a max. distance of 500 mts and max. resistance of 
10 Ohm). 
 
 Main features. 
 VproX 1000 system has the possibility: 
~ to store up to 1000 keys/Tags. 
~ to connect up to 8 Readers Module ART.847 / 848 for contact Key or ART.849 for Proximity Key ( 2 each main door) 
and  connection can be made by using 5 standard wires, not shielded, for a max. distance of 200 mts and max. resistance 
of 10 Ohm. 
~ to connect up to 16 additional main door ( by using VproX 1000-A coded from 105 to 120) 
~ to connect up to 100 apartment unit (by using VproX 1000-A device) 
~ to select which main door the key/Tag can access (up to 20 doors, 4 included on board and 16 additional main door by 
using VproX 1000-A device) 
~ to select which apartment door the key/Tag can access 
~ to select one of  4 "time band" during which it will be possible to entry 
~ to store one or more Master key/Tag (with it, it is possible to entry everywhere)  
~ to store more than one key/Tag each apartment (no limit) 
~ to store the same key/Tag in difference apartments 
~ to open main door and apartment door with the same key/Tag 
~ to modify the setting parameters of a stored key/Tag 
~ to delete a lost key/Tag 
~ to keep in memory the last 512 accesses (Data Report), scroll them directly on display or download  them in a printer or 
a PC. 
~ to connect a Videx printer Art.450 (by 25pole connector) to read out: 
   - No. of key/tag (3 digits: from 0 to 999 or ??? when not stored) 
   - No. of key/Tag where it allows to entry (2 digit: from 01 to 99 or "M" if it is a Master key/Tag) 
   - No. of main door (2 digits: from D1 to D20) or No. of  apartment unit (2 digits: from U01 to U99) 
   - Qualification of  the key/Tag ( 1 character: Y=yes, N=no) 
   - Time of access (hh:mm) 
   - Date of access (MM/DD) 
~ to connect a PC (by 9pole connector standard RS232 interface and a program disk): 

- to write the users name on a Database 
- to have all data report stored in a file (on Diskette or Hard Disk) 
- to see on screen (or to print ) all data report with the respective user name   
- to see on screen (or to print ) the data report about only a single key/Tag 

~ to connect an additional Button to close Relay 1 contact for programmed time 
~ to connect an ALARM unit 
 
Highest protection against sabotage: the Control Unit " VproX 1000" (with built in all relays) is remote from the Readers 
Art.847/848/849; after 5 attempts with unstored or not qualified key/Tag, an alarm will be caused (ALARM relay will be 
on) and the Control Unit will disable all Readers (self protection) for programmed time, all data will be stored into own 
memory, or paper by printer (if installed) or PC (if connected). 
High protection of Key/Tag DATA: all Key/Tag DATA are stored in two different memory (EEPROM); one remain on 
VproX 1000 board (colour BLACK) and one can be use as spare (colour RED) in case something will happen to the first 
one. 
 

Содержание VproX 1000-M

Страница 1: ... the same key Tag to modify the setting parameters of a stored key Tag to delete a lost key Tag to keep in memory the last 512 accesses Data Report scroll them directly on display or download them in a printer or a PC to connect a Videx printer Art 450 by 25pole connector to read out No of key tag 3 digits from 0 to 999 or when not stored No of key Tag where it allows to entry 2 digit from 01 to 9...

Страница 2: ...ystem and disconnect the BACKUP MEMORY keep it in a safe place At the end power up the System and the VproX 1000 is ready to work OPERATION In stand by operation the System shows on DISPLAY the current TIME and DATA when a user inserts a stored key Tag in a Reader Main door or Apartment door the Printer if present will print the operation the LEDs on Reader will be green and a sharp beep will give...

Страница 3: ...nication port From the main screen select SETUP Select the port settings tab Select the new communications port and click OK Number of doors To setup the number of doors on the system From the main screen select setup Select the No of doors tab Select the number of doors and press OK Main screen From the main screen it is possible to view the last five users of the system It will show the door the...

Страница 4: ...RINT button A standard print dialogue box will appear Simply choose the printer and press print Finally when the UPDATE IN REAL TIME box is ticked new entries will appear on the screen as they happen If this box is not ticked the entries will be recorded in the database but will not appear on the screen Setup The setup page is split into the following sections Port Settings Choose the communicatio...

Страница 5: ... is necessary to upload to the CPU every time you add edit or delete keys and when ever changes are made to door open times and time bands To Upload to the Vprox1000 From the main screen select setup Press Upload from CPU A password box will appear Enter the CPU master code Factory default is 11111111 But this may have been changed at the time of installation The master code can only be changed fr...

Страница 6: ...in screen select setup Select the Users tab Select Delete a user A new box will appear which will allow you to either search for the user you wish to delete by user name or by key number Once a user has been selected press the OK button The users details will appear on the screen A message box will appear asking you if you are sure you want to delete the user At this point you can either go back a...

Страница 7: ...7 ...

Страница 8: ...8 ...

Страница 9: ...V a c at the end the system will provide to charge it to select the Relay output time from 2 to 5 sec by means 8th Dip switch to connect an additional Button to close Relay 1 contact for programmed time to supply directly d c or a c Lock 12V 1 6A max 9 Module Box facility Red LED facility to signals a damage on the output stage connected with the BUS in case of fault it helps to find the damaged U...

Страница 10: ...FF ON ON ON OFF 58 OFF ON OFF ON ON ON OFF 59 ON ON OFF ON ON ON OFF 60 OFF OFF ON ON ON ON OFF 61 ON OFF ON ON ON ON OFF 62 OFF ON ON ON ON ON OFF 63 ON ON ON ON ON ON OFF 64 OFF OFF OFF OFF OFF OFF ON 65 ON OFF OFF OFF OFF OFF ON 66 OFF ON OFF OFF OFF OFF ON 67 ON ON OFF OFF OFF OFF ON 68 OFF OFF ON OFF OFF OFF ON 69 ON OFF ON OFF OFF OFF ON 70 OFF ON ON OFF OFF OFF ON 71 ON ON ON OFF OFF OFF ON...

Страница 11: ...11 ...

Отзывы: