System has a DISPLAY that shows all data during programming mode; while during "stand by" it displays the time and
date.
System has a keypad 4x4 buttons for following:
- Program Master code to access to the programming menu
- Program up to 1000 keys/Tags with possibility to select which apartment door, which main door and in which "time
band" the key/Tag can access
- Delete one or more keys/Tags
- Program the ALARM relay time ( 1-255 secs)
- Program each other relay time ( 1-255 secs)
- Program 4 "time band" ( hh:mm START, hh:mm STOP and week DAY each) during which it will be possible to use a
stored keys/Tags with this facility
- Program "Hours, Date and week Day".
INITIALIZATION
Note:
In order to avoid electric discharges which could give problems to the system, we suggest not to install the cables
together with other power lines (AC electric lock cables, mains cables, lift cables, etc) or use a shielded cable for the
Readers connection and for the BUS line. When the installation is concluded and carried out according to wiring diagram,
place the jumper J1 (battery back-up for Clock/Calendar) in ON position.
If you have installed some VproX 1000-A units, you must set in binary code its Dip-switch bank (No. of Unit and Relay
time) before power up the system. To program it as an Apartment Unit you have to choose Nr. from 1 to 99 and from 105
to 120 to program it as an additional Main door Unit .
Power up the System and program it by " VproX 1000 PROGRAMMING" Flow Chart. Then, power off the System and
disconnect the "BACKUP MEMORY" (keep it in a safe place). At the end, power up the System and the VproX 1000 is
ready to work.
OPERATION
In stand by operation the System shows on DISPLAY the current TIME and DATA; when a user inserts a "stored
key/Tag" in a Reader (Main door or Apartment door) , the Printer (if present) will print the operation, the LEDs on
Reader will be green and a sharp "beep" will give out. If it's not a "stored key/Tag" the display will show ‘???’, the LEDs
on Reader will be red and a low "beep" will give out; the Printer will print the operation with the "???" instead of key/Tag
No. . All Data Report will be stored into memory (Eeprom) present in the System.
If the "BUS FAIL" LED is ON means that there are problems in the serial BUS connection with the Apartment Unit
VproX 1000-A.
If the "PE" LED is ON means that the paper is empty or the Printer is not connect.
If you have the "internal Printer" Art.450, you can advance the paper by pressing "FF" button.
If you want to know if a key/Tag is stored, keep pressed "#" button ( Display will show "TEST KEY"), release button and
insert the unknown key/Tag ( DISPLAY shows the key/Tag number ); at the end repeat the same procedure to came back
in stand-by mode.
If you want to download all Data Report Memory (the last 512 accesses) you must press ‘D’ button on the keypad (
“REPORT? 1=LPT - 2=DISPLAY” on display) and press ‘1’ if you want to send all to the printer or press ‘2’ to scroll
them on display by using "*" button.
TECHNICAL SPECIFICATIONS
Storage
capacity :1000
keys
Working
voltage :
12V
d.c.
+/-
10%
Stand-by
absorption
:
about
350mA
Operation
absorption
:
max.
450mA
Operation absorption with internal Printer
: max. 1.5A
Working
temperature
:
-10
+50
C
degrees