System has a DISPLAY that shows all data during programming mode; while during "stand by" it displays the time and 
date. 
System has a keypad 4x4 buttons for following: 
- Program Master code to access to the programming menu 
- Program up to 1000 keys/Tags with possibility to select which apartment door, which main door and in which "time 
band" the key/Tag can access 
- Delete one or more keys/Tags  
- Program the ALARM relay time ( 1-255 secs) 
- Program each other relay time ( 1-255 secs) 
- Program  4 "time band" ( hh:mm START, hh:mm STOP and week DAY each) during which it will be possible to use a 
stored keys/Tags with this facility 
- Program "Hours, Date and week Day". 

 

INITIALIZATION 

Note:

 In order to avoid electric discharges which could give problems to the system, we suggest not to install the cables 

together with other power lines (AC electric lock cables, mains cables, lift cables, etc) or use a shielded cable for the 
Readers connection and for the BUS line. When the installation is concluded and carried out according to wiring diagram, 
place the jumper J1 (battery back-up for Clock/Calendar) in ON position. 
If you have installed some VproX 1000-A units, you must set in binary code its Dip-switch bank (No. of Unit and Relay 
time) before power up the system. To program it as an Apartment Unit you have to choose Nr. from 1 to 99 and from 105 
to 120 to program it as an additional Main door Unit . 
Power up the System and program it by " VproX 1000 PROGRAMMING" Flow Chart. Then, power off the System and 
disconnect the "BACKUP MEMORY" (keep it in a safe place). At the end,  power up the System and the VproX 1000 is 
ready to work. 
 

OPERATION 

In stand by operation the System shows on  DISPLAY  the current TIME and DATA; when a user inserts a "stored 
key/Tag" in a Reader (Main door or Apartment door) , the Printer (if present) will print the operation, the LEDs on 
Reader will be green and a sharp "beep" will give out. If it's not a "stored key/Tag" the display will show ‘???’, the LEDs 
on Reader will be red and a low "beep" will give out; the Printer will print the operation with the "???" instead of key/Tag 
No. . All Data Report will be stored into memory (Eeprom) present in the System.  
If the "BUS FAIL" LED is ON means that there are problems in the serial BUS connection with the Apartment Unit 
VproX 1000-A. 
If the "PE" LED is ON means that the paper is empty or the Printer is not connect. 
If you have the "internal Printer" Art.450, you can advance the paper by pressing "FF" button.  
If you want to know if a key/Tag is stored, keep pressed "#" button ( Display will show "TEST KEY"), release button and 
insert the unknown key/Tag ( DISPLAY shows the key/Tag number ); at the end repeat the same procedure to came back 
in stand-by mode. 
If you want to download all Data Report Memory (the last 512 accesses) you must press ‘D’ button on the keypad ( 
“REPORT?  1=LPT  -   2=DISPLAY” on display) and press ‘1’  if you want to send all to the printer or press ‘2’ to scroll 
them on display by using "*" button.  
 

 
 
 

TECHNICAL SPECIFICATIONS 

Storage 

capacity       :1000 

keys 

Working 

voltage       : 

12V 

d.c. 

+/- 

10% 

Stand-by 

absorption 

      : 

about 

350mA 

Operation 

absorption 

      : 

max. 

450mA 

Operation absorption with internal Printer 

 

 

 

: max. 1.5A 

Working 

temperature 

      : 

-10 

+50 

degrees 

Содержание VproX 1000-M

Страница 1: ... the same key Tag to modify the setting parameters of a stored key Tag to delete a lost key Tag to keep in memory the last 512 accesses Data Report scroll them directly on display or download them in a printer or a PC to connect a Videx printer Art 450 by 25pole connector to read out No of key tag 3 digits from 0 to 999 or when not stored No of key Tag where it allows to entry 2 digit from 01 to 9...

Страница 2: ...ystem and disconnect the BACKUP MEMORY keep it in a safe place At the end power up the System and the VproX 1000 is ready to work OPERATION In stand by operation the System shows on DISPLAY the current TIME and DATA when a user inserts a stored key Tag in a Reader Main door or Apartment door the Printer if present will print the operation the LEDs on Reader will be green and a sharp beep will give...

Страница 3: ...nication port From the main screen select SETUP Select the port settings tab Select the new communications port and click OK Number of doors To setup the number of doors on the system From the main screen select setup Select the No of doors tab Select the number of doors and press OK Main screen From the main screen it is possible to view the last five users of the system It will show the door the...

Страница 4: ...RINT button A standard print dialogue box will appear Simply choose the printer and press print Finally when the UPDATE IN REAL TIME box is ticked new entries will appear on the screen as they happen If this box is not ticked the entries will be recorded in the database but will not appear on the screen Setup The setup page is split into the following sections Port Settings Choose the communicatio...

Страница 5: ... is necessary to upload to the CPU every time you add edit or delete keys and when ever changes are made to door open times and time bands To Upload to the Vprox1000 From the main screen select setup Press Upload from CPU A password box will appear Enter the CPU master code Factory default is 11111111 But this may have been changed at the time of installation The master code can only be changed fr...

Страница 6: ...in screen select setup Select the Users tab Select Delete a user A new box will appear which will allow you to either search for the user you wish to delete by user name or by key number Once a user has been selected press the OK button The users details will appear on the screen A message box will appear asking you if you are sure you want to delete the user At this point you can either go back a...

Страница 7: ...7 ...

Страница 8: ...8 ...

Страница 9: ...V a c at the end the system will provide to charge it to select the Relay output time from 2 to 5 sec by means 8th Dip switch to connect an additional Button to close Relay 1 contact for programmed time to supply directly d c or a c Lock 12V 1 6A max 9 Module Box facility Red LED facility to signals a damage on the output stage connected with the BUS in case of fault it helps to find the damaged U...

Страница 10: ...FF ON ON ON OFF 58 OFF ON OFF ON ON ON OFF 59 ON ON OFF ON ON ON OFF 60 OFF OFF ON ON ON ON OFF 61 ON OFF ON ON ON ON OFF 62 OFF ON ON ON ON ON OFF 63 ON ON ON ON ON ON OFF 64 OFF OFF OFF OFF OFF OFF ON 65 ON OFF OFF OFF OFF OFF ON 66 OFF ON OFF OFF OFF OFF ON 67 ON ON OFF OFF OFF OFF ON 68 OFF OFF ON OFF OFF OFF ON 69 ON OFF ON OFF OFF OFF ON 70 OFF ON ON OFF OFF OFF ON 71 ON ON ON OFF OFF OFF ON...

Страница 11: ...11 ...

Отзывы: