PCAN-Wireless Gateway – User Manual
55
Reload Default Settings:
With the Reload button you can restore the device to its factory
defaults. During this process the login settings, all device and
communication interface settings along with existing routes will be
restored to the states they were in at the time of product delivery.
The current configuration is overwritten within that process. In
addition, the access data will be reset to the default values (see the
label on the upper side of the device). The PCAN-Gateway is then
reachable under the default IP address.
Auto Power Off:
With this form you can activate the
Auto Power Off
function. If
enabled, the device will switch off, if there is no voltage applied to
terminal 15 for more than approx. 5 seconds. It restarts
automatically if CAN traffic is detected or a High level is applied to
terminal 15 (Wake-up pin).
Activate the function via the checkbox and save the settings with
Save Settings .
Note:
As long as a voltage is applied to terminal 15, the
Power Off
from the navigation causes only a short-term
shutdown. Because voltage is applied, the device will restart
immediately.