MU-Thermocouple1 CAN FD – User Manual
24
6.2
Internal Termination
The CAN bus termination for the CAN connection can be set with
the
switch block
on the board. By default, the switch is set to
off
.
Tip:
We recommend adding termination at the CAN cabling, for
example with termination adapters (e.g. PCAN-Term). Thus,
CAN nodes can be flexibly connected to the bus.
Do the following to activate the termination:
Attention!
Electrostatic discharge (ESD) can damage or destroy
components on the card. Take precautions to avoid ESD.
1.
Disconnect the power supply.
2.
Remove all connected cables from the measuring unit.
3.
Remove the two screws of the D-Sub connector and the four
screws on the front panel to remove it.
4.
Remove the two upper screws of the back panel and remove
the housing cover.
5.
Pull the right board with the D-Sub connector out of the
connectors of the motherboard. You can also remove the
entire board from the case.
6.
Locate the switch on the board using the following figure: