background image

Operation with Maxa Beam Optical Filters

The Maxa Beam optional filters utilize a quick disconnect snap lock feature for ease and speed of 
installation or removal. There is a small blue indicator located on the top of the light housing just behind the 
front lens ring. This indicator is to alert the operator that the light is on when being operated with one of the 
filters installed.

To attach filters
1)

Line up tabs on filter with slot on searchlight lens attachment ring.

2)

Place filter over front of the searchlight.

3)

Turn filter counter clockwise until it is seated and it locks in place.

Remote Operation

The searchlight models MBS-450 and the MBS-430 have an 8-pin connector installed on the left rear 
corner of the light next to the power connector. See figure 5 for pin out identification. 

The remote control capable searchlights allow the operator to hard wire the searchlight to a MBA-8425 
remote control handle or to a auxiliary control panel. This allows remote programming and operation of all 
standard functions. Remote power and control cables are available in 25’ and 50’ lengths.

All contact closures (switches) used for remote operation must be momentary, normally open. During 
operation, the microprocessor is constantly scanning the status of all input lines from the remote control 
input connector. When the closure of one of the remote switches is detected, the microprocessor executes 
the appropriate command. Input lines 3,4,5,6 and 7 are active high. These lines have internal pull down 
resistors.
 
Line 1 (pin 1) is an output line which provides power for the on/off and other remote functions. Caution: 
There is power applied to line 1 (pin 1) at any time there is power supplied to the light, even when the light 
is off. This line is tied directly to the power input connector. When wiring the on/off switch and remote 
control switches, line 1 (pin 1) must be tied to one side of all switches in parallel. Line 2 (pin 2) is chassis 
ground and should be wired to the cable shield for long cable runs. Line 3 (pin 3) from the on/off switch is 
also scanned during the operation. When the on/off switch is closed again after the light has been turned 
on, the microprocessor disables all normal operational modes and is then in the programming mode. If one 
of the other remote switches is closed, while the on/off switch is closed one of the user functions will be 
reprogrammed.

Maintenance

The only maintenance required on the Maxa Beam Searchlight is to periodically clean the body with a 
damp cloth and to keep the front lens cover clean. Clean the front lens with window cleaner.

Lamp Focus

If the searchlight is dropped or receives any heavy impact from transportation or shipping, it may be 
necessary to refocus the lamp to insure proper operation and maximum output. Refocusing of the lamp 
requires centering the lamp within the reflector. 

1)

Using a 1/16” allen driver remove the 2 focus access screws, one on the right front side of the main 
body and one just left of the front of the handle (see fig. 4). 

2)

Shine the light beam onto a flat surface about 50 feet away. 

3)

Insert the allen driver into one of the focus access holes. A slight rotation and/or side to side movement 
may be required until the allen drive is properly seated into the adjustment screw. 

4)

After the allen driver has been inserted into the adjustment screw, turn the allen driver to center the 

5

Содержание Maxa Beam

Страница 1: ... Held Xenon Searchligh Operation Manual Copyright 2002 by Peak Beam Systems Inc BEAM E mail sales peakbeam com Website www peakbeam com techsupport peakbeam com High Intensity Searchlights PEAK SYSTEMS INC ...

Страница 2: ...5 Lamp Focus 5 Lamp Replacement 6 Programming 6 Chargers 8 Batteries 10 Optical Filters 11 Maxa Beam Patterns with Diffusion Filters Fig 1 13 Relative Spectral Radiation Xenon Lamp Fig 2 13 Internal Transmittance of MBA IR Filters Fig 3 14 Lamp Focus Access Points Fig 4 14 Remote Control Pin Layout Fig 5 15 Troubleshooting 15 Returns to the Factory 17 Equipment and Accessories 18 1 ...

Страница 3: ...nt Snap on rechargeable battery modules Rechargeable battery belt Up to 2 hours of operation on one battery Quick charger recharges batteries in 2 1 2 hours Multi Voltage charger operates on 12 36 VDC and 100 240 VAC Stationary power supply operates searchlight from 120 or 220 VAC Customizable strobe function Remote models MBS 430 450 allow remote control of Beam intensity Beam Size Flexible mount...

Страница 4: ...tch mode power supply is factory set and requires no adjustment even after a lamp change has occurred as the control circuitry is self calibrating Internal power regulation keeps both the intensity and color of the beam constant as the voltage from the battery drops Warnings Do not operate this light in an explosive environment Do not look directly into the light at close distances Do not immerse ...

Страница 5: ...ld this setting for about 3 seconds then the intensity will drop to the programmed power setting To change the size of the searchlight s beam 1 Rock the beam conditioning switch to the rear to widen beam Rock the beam conditioning switch forward to narrow beam When you obtain the beam width you wish release switch Set searchlight intensity 1 To increase the intensity of the searchlight to high bea...

Страница 6: ...and other remote functions Caution There is power applied to line 1 pin 1 at any time there is power supplied to the light even when the light is off This line is tied directly to the power input connector When wiring the on off switch and remote control switches line 1 pin 1 must be tied to one side of all switches in parallel Line 2 pin 2 is chassis ground and should be wired to the cable shield...

Страница 7: ...al you could set it so that it would come on in strobe mode with a wide beam When you receive your searchlight from the factory it will operate as follows It will come on in normal power mode Rocking the conditioning switch forward will narrow the focus of the beam Rocking the conditioning switch back will widen the focus of the beam Rocking the conditioning switch to the left will place it in bat...

Страница 8: ...ng when moving out of the full spot position then the spot position was set beyond the point at which the lamp is physically able to move If this occurs the spot position should be reset to a point at or within the physical limits of the lamp s travel F Setting the widest flood of the searchlight Note If you notice a delay before the lamp starts moving when moving out of the full flood position th...

Страница 9: ...r Maxa Beam batteries or any other device This model charger may be adjusted for use with either a 110 vac or 220 vac power input supply The MBP 3100 is a single rate constant current trickle charger which will charge the MBP 1207 battery overnight Charging 1 Set input supply voltage switch to the desired voltage 2 Plug the wall adapter into the wall outlet and connect its output connector to the ...

Страница 10: ...es 14 hours place the battery with or without searchlight attached on top of the charger by lowering it straight down Do not slide in horizontally The indicator lights will flash amber turning green when the battery is charged For standby use the battery may be left on the charger 5 For a 2 5 hour quick charge connect the male end of the pigtail output connector to the battery The indicator lights...

Страница 11: ...ith searchlight into charger first insert connector end of battery into charger so that bottom keeper is in the bottom latch Push searchlight towards charger until top latch completely closes over top keeper 5 Install safety strap 6 To remove battery or battery and searchlight hold device remove safety strap push up on top latch to free top keeper Lift device up slightly to disengage bottom keeper...

Страница 12: ...g for hands free transportation The safety strap with hook and loop fastener should always be used when the searchlight is clipped to the battery belt To change from left handed to right handed operation just reverse the orientation of the output connector from the top to the bottom Optical Filters Several customized selective band pass filters are available for the Maxa Beam Searchlight Maxa Beam...

Страница 13: ...ut allows a sharp collimated beam at its spot setting This filter can also be furnished on any of our covert IR filters See the MBA 3075 Stacking Adapter for use with IR filters MBA 3020 Peripheral Vision Filter Provides a hot center beam with a wide band of light extending to either side Useful for wide area search applications Cuts down on the amount of light which is reflected back at the opera...

Страница 14: ...Maxa Beam Patterns With Diffusion Filters Figure 1 Relative Spectral Radiation Xenon Lamp Figure 2 13 Wide Flood With and Without MBA 3000 MBA 3020 Peripheral Vision Filter ...

Страница 15: ...Internal Transmittance of IR Filters Figure 3 Lamp Focus Access Points Figure 4 14 Y Axis Access Point X Axis Access Point ...

Страница 16: ...imits Not Set Correctly Light beam will not focus to the full flood position Defective Controller Light comes on but hi low beam and focus do not work Restore Factory Settings or Return Light For Repair Limits Not Set Correctly or Defective Servo or Controller Light comes on but focus will not work Check Power Source and Power Cord No Power Nothing happens when power button is pressed Return Light...

Страница 17: ...r an RMA Defective Charger The flashing green indication light stays on for more than 16 hours during the recondition cycle Normal Charger gets hot during recondition cycle Call Factory for an RMA Defective Charger Indicator turns solid amber instead of flashing amber when battery is set on top without its tail connected Clean Contacts or Turn Battery Around Dirty Trickle Charge Contacts or Batter...

Страница 18: ...ble Cause Symptom Returns To The Factory All factory returns must have a Return Materials Authorization Number RMA We can take no responsibility for items returned without an authorization number Please contact us as shown below to receive a RMA form Have the following information available when you call Serial numbers of units to be returned If known date of purchase and place where purchased Rea...

Страница 19: ... 240 VAC 50 60hz with surface mounting brackets MBP 5600 Desktop Version 100 240 VAC 50 60 Hz MBP 5600 V 5600 Vertical Mounting Option Filters MBA 1500 Amber Fog Smoke MBA 3010 Partial Diffusion MBA 1715 Semi Covert Infrared MBA 3020 Peripheral Vision MBA 1850 Covert Infrared MBA 3075 Filter Stacking Adapter MBA 1900 Super Covert Infrared MBA 6100 Filter Pouch MBA 1950 Ultra Covert Infrared MBA 21...

Страница 20: ...Maxa Beam is a Trademark of Peak Beam Systems Inc All other Trademarks are the property of their respective owners 19 ...