Remote Control Pin Layout
Pin #
Function
1
12 VDC
2
Ground
3
On/Off
4
Hi/Low Beam
5
Focus Narrow
6
Focus Wide
7
Strobe/Battery Saver Mode
8
Servo Input
Pins 3, 4, 5, 6, & 7 require a momentary 12 volt input to activate their related function.
Consult the factory for utilization of pin 8.
Figure 5
Troubleshooting
Return Light For Repair
400 Series Searchlight
Reduce Supply Voltage
Supply Voltage Too High
Light comes on but will not
change power level
Call Factory for Instructions on
Reseating Lamp
or
Call Factory for Instructions
Lamp is Not Seated in Socket
Completely
or
Limits Not Set Correctly
Light beam will not focus to the
full flood position
Defective Controller
Light comes on but hi-low beam
and focus do not work
Restore Factory Settings
or
Return Light For Repair
Limits Not Set Correctly
or
Defective Servo or Controller
Light comes on but focus will not
work
Check Power Source and Power
Cord
No Power
Nothing happens when power
button is pressed
Return Light for Repair
Defective Igniter or Defective
Regulator
Lamp does not strike but relay can
be heard to work
Change Lamp
Bad Lamp
Lamp strikes but does not ignite
Charge Battery
Low Battery
Light ignites but goes out when
switched to high output
Charge Battery
Low Battery
Searchlight lights but goes out
after a second or two
Remedy
Probable Cause
Symptom
15
1
2
5
4
3
8
7
6