Peak Beam Systems Maxa Beam Скачать руководство пользователя страница 5

Searchlight Operation

Setup

1)

Locate searchlight, battery and power cable. 

2)

Inspect items for physical damage.

3)

Attach searchlight to battery by lining up 
round feet of searchlight over round holes on 
the top of the battery (a). Lower the searchlight 
into the holes and then (b) slide the searchlight 
towards connector end of battery . Check for 
positive lock by sliding searchlight away from 
connector end of battery. If properly locked 
it should not slide.

4)

Attach battery carrying strap to diagonally 
opposite ears on battery.

5)

Attach male end of power cable to connector on 
battery. These are keyed; never force cable connections. To lock rotate only the locking ring clockwise.

6)

Attach female end of power cable to right hand male connector on searchlight. These are keyed; never 
force cable connections. To lock, rotate only the locking ring clockwise.

To release searchlight from battery pack

1)  Lift lock release lever under searchlight handle, located at the rear of the handle and slide searchlight 

forward away from connection end of battery.

To turn searchlight on

1)

Momentarily press the red power on/off switch 
located on the handle at front. You should hear a 
sparking noise and the light will light. If the light 
does not light in 5 seconds press the red button 
again to stop the starting process and see the 
troubleshooting section of this manual. 

2)

The searchlight will light at high beam and hold 
this setting for about 3 seconds, then the intensity 
will drop to the programmed power setting.

To change the size of the searchlight’s beam 

1)

Rock the beam conditioning switch to the rear to widen 
beam. Rock the beam conditioning switch forward to 
narrow beam. When you obtain the beam width you wish, release switch.

Set searchlight intensity

1)

To increase the intensity of the searchlight to high beam, rock the beam conditioning switch once to the 
right. When you release the beam conditioning switch the intensity will return to 
normal. (the operation of this function can be modified, see the programming section)

2)

To decrease the intensity of the searchlight to battery saver mode you must first activate this function 
as explained in the programing section of this manual. After activation, rock the beam conditioning to 
the left. This will set the light into battery saver mode. To return to normal intensity rock the beam 
conditioning switch to the left again.

Override low voltage protection

1)

The Maxa Beam searchlights automatically shut down before they discharge a battery enough to 
damage it. At this point, there are usually several minutes of power left in the battery which can be 
accessed in an emergency by pushing the power button and holding it down. Please note this 
procedure may damage the battery to the point that it will not accept a charge.

4

a

b

Lock Release Lever

Lock Release Lever

Power Switch

Beam Conditioning
Switch

Note: This is a four

position joy s

Do not push bu

down.

Power Switch

Beam Conditioning 
Switch

Note: This is a four 
position joy stick.  Do 
not push button down.

Содержание Maxa Beam

Страница 1: ... Held Xenon Searchligh Operation Manual Copyright 2002 by Peak Beam Systems Inc BEAM E mail sales peakbeam com Website www peakbeam com techsupport peakbeam com High Intensity Searchlights PEAK SYSTEMS INC ...

Страница 2: ...5 Lamp Focus 5 Lamp Replacement 6 Programming 6 Chargers 8 Batteries 10 Optical Filters 11 Maxa Beam Patterns with Diffusion Filters Fig 1 13 Relative Spectral Radiation Xenon Lamp Fig 2 13 Internal Transmittance of MBA IR Filters Fig 3 14 Lamp Focus Access Points Fig 4 14 Remote Control Pin Layout Fig 5 15 Troubleshooting 15 Returns to the Factory 17 Equipment and Accessories 18 1 ...

Страница 3: ...nt Snap on rechargeable battery modules Rechargeable battery belt Up to 2 hours of operation on one battery Quick charger recharges batteries in 2 1 2 hours Multi Voltage charger operates on 12 36 VDC and 100 240 VAC Stationary power supply operates searchlight from 120 or 220 VAC Customizable strobe function Remote models MBS 430 450 allow remote control of Beam intensity Beam Size Flexible mount...

Страница 4: ...tch mode power supply is factory set and requires no adjustment even after a lamp change has occurred as the control circuitry is self calibrating Internal power regulation keeps both the intensity and color of the beam constant as the voltage from the battery drops Warnings Do not operate this light in an explosive environment Do not look directly into the light at close distances Do not immerse ...

Страница 5: ...ld this setting for about 3 seconds then the intensity will drop to the programmed power setting To change the size of the searchlight s beam 1 Rock the beam conditioning switch to the rear to widen beam Rock the beam conditioning switch forward to narrow beam When you obtain the beam width you wish release switch Set searchlight intensity 1 To increase the intensity of the searchlight to high bea...

Страница 6: ...and other remote functions Caution There is power applied to line 1 pin 1 at any time there is power supplied to the light even when the light is off This line is tied directly to the power input connector When wiring the on off switch and remote control switches line 1 pin 1 must be tied to one side of all switches in parallel Line 2 pin 2 is chassis ground and should be wired to the cable shield...

Страница 7: ...al you could set it so that it would come on in strobe mode with a wide beam When you receive your searchlight from the factory it will operate as follows It will come on in normal power mode Rocking the conditioning switch forward will narrow the focus of the beam Rocking the conditioning switch back will widen the focus of the beam Rocking the conditioning switch to the left will place it in bat...

Страница 8: ...ng when moving out of the full spot position then the spot position was set beyond the point at which the lamp is physically able to move If this occurs the spot position should be reset to a point at or within the physical limits of the lamp s travel F Setting the widest flood of the searchlight Note If you notice a delay before the lamp starts moving when moving out of the full flood position th...

Страница 9: ...r Maxa Beam batteries or any other device This model charger may be adjusted for use with either a 110 vac or 220 vac power input supply The MBP 3100 is a single rate constant current trickle charger which will charge the MBP 1207 battery overnight Charging 1 Set input supply voltage switch to the desired voltage 2 Plug the wall adapter into the wall outlet and connect its output connector to the ...

Страница 10: ...es 14 hours place the battery with or without searchlight attached on top of the charger by lowering it straight down Do not slide in horizontally The indicator lights will flash amber turning green when the battery is charged For standby use the battery may be left on the charger 5 For a 2 5 hour quick charge connect the male end of the pigtail output connector to the battery The indicator lights...

Страница 11: ...ith searchlight into charger first insert connector end of battery into charger so that bottom keeper is in the bottom latch Push searchlight towards charger until top latch completely closes over top keeper 5 Install safety strap 6 To remove battery or battery and searchlight hold device remove safety strap push up on top latch to free top keeper Lift device up slightly to disengage bottom keeper...

Страница 12: ...g for hands free transportation The safety strap with hook and loop fastener should always be used when the searchlight is clipped to the battery belt To change from left handed to right handed operation just reverse the orientation of the output connector from the top to the bottom Optical Filters Several customized selective band pass filters are available for the Maxa Beam Searchlight Maxa Beam...

Страница 13: ...ut allows a sharp collimated beam at its spot setting This filter can also be furnished on any of our covert IR filters See the MBA 3075 Stacking Adapter for use with IR filters MBA 3020 Peripheral Vision Filter Provides a hot center beam with a wide band of light extending to either side Useful for wide area search applications Cuts down on the amount of light which is reflected back at the opera...

Страница 14: ...Maxa Beam Patterns With Diffusion Filters Figure 1 Relative Spectral Radiation Xenon Lamp Figure 2 13 Wide Flood With and Without MBA 3000 MBA 3020 Peripheral Vision Filter ...

Страница 15: ...Internal Transmittance of IR Filters Figure 3 Lamp Focus Access Points Figure 4 14 Y Axis Access Point X Axis Access Point ...

Страница 16: ...imits Not Set Correctly Light beam will not focus to the full flood position Defective Controller Light comes on but hi low beam and focus do not work Restore Factory Settings or Return Light For Repair Limits Not Set Correctly or Defective Servo or Controller Light comes on but focus will not work Check Power Source and Power Cord No Power Nothing happens when power button is pressed Return Light...

Страница 17: ...r an RMA Defective Charger The flashing green indication light stays on for more than 16 hours during the recondition cycle Normal Charger gets hot during recondition cycle Call Factory for an RMA Defective Charger Indicator turns solid amber instead of flashing amber when battery is set on top without its tail connected Clean Contacts or Turn Battery Around Dirty Trickle Charge Contacts or Batter...

Страница 18: ...ble Cause Symptom Returns To The Factory All factory returns must have a Return Materials Authorization Number RMA We can take no responsibility for items returned without an authorization number Please contact us as shown below to receive a RMA form Have the following information available when you call Serial numbers of units to be returned If known date of purchase and place where purchased Rea...

Страница 19: ... 240 VAC 50 60hz with surface mounting brackets MBP 5600 Desktop Version 100 240 VAC 50 60 Hz MBP 5600 V 5600 Vertical Mounting Option Filters MBA 1500 Amber Fog Smoke MBA 3010 Partial Diffusion MBA 1715 Semi Covert Infrared MBA 3020 Peripheral Vision MBA 1850 Covert Infrared MBA 3075 Filter Stacking Adapter MBA 1900 Super Covert Infrared MBA 6100 Filter Pouch MBA 1950 Ultra Covert Infrared MBA 21...

Страница 20: ...Maxa Beam is a Trademark of Peak Beam Systems Inc All other Trademarks are the property of their respective owners 19 ...

Отзывы: