Client Mode (internal network)
•
First, a wireless device must be set as an AP
o
Determine the SSID for the meter.
o
Setting a password is not necessary.
•
Set the meter to Client mode with the following parameters:
o
Net mode: Client
o
SSID: RHW-925 (or used defined) Internet
o
IP: 192.168.0.254
o
Port: 200
Refer to
Screen 6
.
5.9
Client mode (external network, fixed IP)
•
Simple schematic network:
•
Set the meter to Client mode with the following parameters:
o
Net mode: Client
o
SSID: RHW-925 (or used defined)
o
IP: 192.168.0.254
o
Port: 200
o
Gateway: 192.168.0.1 (download IP Tools from the App Store to learn how
to set this parameter).
•
In the port forwarding settings of your IP router, you can set the parameters for SSID,
IP address and port such as here:
Image 8
•
Enter the needed parameters in
Image 4
of the MeterApp. Set the IP address according
to the required IP address of IP Tools.
Internet
Modem
IP Router
Wireless (AP)