5.11 Ethernet Mode connector network floating (internal or external network)
•
Simple schematic network:
•
Set the meter to Client mode with the following parameters:
o
IP: 192.168.0.254
o
Port: 200
o
Gateway: 192.168.0.1
•
Connect the Ethernet cable to input 3.19 in
Fig. 1
.
5.12 Ethernet Mode connected via wireless bridge network (external network, fixed IP):
•
Simple schematic network:
•
Set the meter to Client mode with the following parameters:
o
IP: 192.168.0.254
o
Port: 200
o
Gateway: 192.168.0.1
•
In the port forwarding settings of your IP router, you can set the parameters for SSID,
IP address and port such as in
Image 8
.
•
Connect the Ethernet cable to input 3.19 in
Fig. 1
.
5.13 Ethernet Mode connected via wireless bridge network (external network, floating
IP):
•
Simple schematic network:
•
Set the meter to Client mode with the following parameters:
o
IP: 192.168.0.254
o
Port: 200
o
Gateway: 192.168.0.1
•
In the port forwarding settings of your IP router, you can set the parameters for SSID,
IP address and port such as in
Image 8
.
•
Apply for a free address at www. Dlinkddns. com. The name of the application will be
transferred to the address input of your IP Router (Image 9)
•
If the Metro App is being used, the required parameters in
Image 4
should be entered using
IP Tools.
•
Connect the Ethernet cable to input 3.19 in
Fig. 1
.
Internet
Modem
IP Router LAN Port
PCE-HT 120
Internet
Modem
IP Router LAN Port
PCE-HT 120
Internet
URL Forwarding
Server
Modem
Wireless
(AP)
IP Router
Wireless
(Bridge)
PCE-HT 120