background image

 

 

©  PCE Instruments 

 

1  Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The 

device may only be used by qualified personnel and repaired by PCE Instruments personnel. 

Damage or injuries caused by non-observance of the manual are excluded from our liability and 

not covered by our warranty. 

 

 

The device must only be used as described in this instruction manual. If used otherwise, 

this can cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, relative 

humidity, …) are within the ranges stated in the technical specifications. Do not expose 

the device to extreme temperatures, direct sunlight, extreme humidity or moisture. 

 

Do not expose the device to shocks or strong vibrations. 

 

The case should only be opened by qualified PCE Instruments personnel. 

 

Never use the instrument when your hands are wet. 

 

You must not make any technical changes to the device. 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, 

no abrasives or solvents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not 

use the device. 

 

Do not use the instrument in explosive atmospheres. 

 

The measurement range as stated in the specifications must not be exceeded under 

any circumstances. 

 

Non-observance of the safety notes can cause damage to the device and injuries to 

the user. 

 

We do not assume liability for printing errors or any other mistakes in this manual. 

 

We expressly point to our general guarantee terms which can be found in our general terms of 

business. 

 

If you have any questions please contact PCE Instruments. The contact details can be found at 

the end of this manual. 

 

 

 

 

Содержание PCE-HT 120

Страница 1: ...hermo Hygrometer User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last chang...

Страница 2: ...toring to factory setting 8 5 7 AP Mode 8 5 8 Client Mode internal network 10 5 9 Client mode external network fixed IP 10 5 10 Client mode external network floating IP 11 5 11 Ethernet Mode connector...

Страница 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Страница 4: ...emperature Measuring range 5 4 49 C 22 3 120 2 F Measuring function PT1000 Measuring range 10 70 C 14 158 F Resolution 0 1 C 0 18 F Accuracy 1 2 C 2 2 F Display LC display Interfaces RS232 SOFT LUT US...

Страница 5: ...9V power input 2 DC 9V power output power supply for the connecting RS232 meter 3 Pt 1000 ohm input 4 Three RS232 inputs 5 Ethernet RJ45 input Basic settings 1 Net Mode 2 SSID 3 Password 4 IP Address...

Страница 6: ...et button 3 3 Humidity Temp sensor 3 13 Stand 3 4 Antenna and antenna socket 3 14 Hanging holes 3 5 Display 3 15 Hanging unit with sticker 3 6 SETUP ENTER BUTTON 3 16 Power interface cable plugs 3 7 E...

Страница 7: ...een 1 start up screen Screen 2 start up screen 5 2 Measurement and settings screens 1 Measurement screen Screen 3 temp humidity measurement Screen 4 Pt1000 measurement Screen 5 settings preview Screen...

Страница 8: ...e device will be initialised over 30 sec The temp humidity measurement screen will then be displayed Screen 3 Press the SETUP ENTER button to enter the settings screen Screen 9 Use the and buttons to...

Страница 9: ...the SETUP ENTER button to confirm your change o Press the button to move the selection to Gateway Gateway o The default gateway is 192 168 0 1 o Press the or button to select the value and then use t...

Страница 10: ...o save the changed settings The device then needs 25 sec to reconnect Screen 7 or 8 before returning to the measurement screen Screen 5 or 6 with the factory settings restored 5 7 AP Mode First instal...

Страница 11: ...re met o Alarm SMS device sends an SMS as an alarm to your smart phone when the conditions on Image 6 are met The Save button Image 5 stores the set settings and returns the device to Image 3 The Wi F...

Страница 12: ...network fixed IP Simple schematic network Set the meter to Client mode with the following parameters o Net mode Client o SSID RHW 925 or used defined o IP 192 168 0 254 o Port 200 o Gateway 192 168 0...

Страница 13: ...Store to learn how to set this parameter In the port forwarding settings of your IP router you can set the parameters for SSID IP address and port such as in Image 8 Apply for free transfer to www noi...

Страница 14: ...t cable to input 3 19 in Fig 1 5 13 Ethernet Mode connected via wireless bridge network external network floating IP Simple schematic network Set the meter to Client mode with the following parameters...

Страница 15: ...r serial port The 16 digits data stream will be displayed in the following format D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 5 14 1 Digit chart D15 Start word D14 4 D13 1 9 D12 D11 Display...

Страница 16: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Страница 17: ...583 975 114 Fax 49 0 2903 976 99 9971 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce instruments com info pce instruments co uk info pce italia it www pce instruments com deutsch www pce instrumen...

Отзывы: