Model Number
EX611A20
CHARGE OUTPUT ACCELEROMETER
Revision: D
ECN #: 46623
Performance
ENGLISH
SI
Sensitivity(± 5 %)
10 pC/g
1.02 pC/(m/s²)
Measurement Range
± 200 g pk
± 1962 m/s² pk
Frequency Range(± 5 %)
2.8 kHz
2.8 kHz
[4]
Frequency Range
(+10 %)
3.7 kHz
3.7 kHz
[4]
Resonant Frequency
>17 kHz
>17 kHz
[1]
Non-Linearity
≤
1 %
≤
1 %
[5]
Transverse Sensitivity
≤
5 %
≤
5 %
[6]
Environmental
Overload Limit(Shock)
± 5000 g pk
± 49,050 m/s² pk
Temperature Range
-65 to +1200 °F
-54 to +650 °C
[2]
Temperature Range
-165 to +1300 °F
-109 to +704 °C
[3]
Temperature Response
See Graph
See Graph
[1]
Base Strain Sensitivity
0.005 g/µ
ε
0.05 (m/s²)/µ
ε
[1]
Radiation Exposure Limit(Integrated Neutron Flux)
1 E10 N/cm²
1 E10 N/cm²
Radiation Exposure Limit
(Integrated Gamma Flux)
1 E8 rad
1 E8 rad
Hazardous Area Approval
Ex ia IIC T6 . . . T 710°C Ga
Ex ia IIC T6 . . . T 710°C Ga
Hazardous Area Approval
IECEx Ex ia IIC T6 . . . T
710°C Ga
IECEx Ex ia IIC T6 . . . T
710°C Ga
Electrical
Capacitance(Pin to Pin)
320 pF
320 pF
[1]
Capacitance
(Pin to Case)
360 pF
360 pF
[1]
Insulation Resistance(Pin to Case 70° F)
>10
9
Ohm
>10
9
Ohm
[1]
Insulation Resistance
(Pin to Pin 70° F)
>10
9
Ohm
>10
9
Ohm
Insulation Resistance
(Pin to Pin 900° F)
>100 kohm
>100 kohm
Insulation Resistance
(Pin to Pin 1200° F)
>20 kohm
>20 kohm
Output Polarity
Differential
Differential
Physical
Sensing Element
UHT-12™
UHT-12™
Sensing Geometry
Shear
Shear
Housing Material
Inconel
Inconel
Sealing
Hermetic
Hermetic
Size (Height x Length x Width)
.787 in x 1.465 in x 1.456 in
20 mm x 37 mm x 37 mm
Weight(without cable)
6.3 oz
180 gm
[1]
Electrical Connector
LEMO PCA.0S.302.CLLC42 LEMO PCA.0S.302.CLLC42
Electrical Connection Position
Side
Side
Cable Length
10 ft
3 m
Cable Type
MI Hardline Cable
MI Hardline Cable
Mounting
Through Hole
Through Hole
[7]
All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.
ICP
®
is a registered trademark of PCB Group, Inc.
OPTIONAL VERSIONS
Optional versions have identical specifications and accessories as listed for the standard model
except where noted below. More than one option may be used.
NOTES:
[1] Typical.
[2] Continuous
[3] Extreme
[4] Low frequency response is determined by external signal conditioning electronics.
[5] Zero-based, least-squares, straight line method.
[6] Transverse sensitivity is typically
≤
3%.
[7] See PCB Declaration of Conformance PS122 for details.
SUPPLIED ACCESSORIES:
Model 081A115 M6 x 1 x 25 mm long (1)
Model ICS-1 NIST-traceable single-axis amplitude response calibration from 600 cpm (10 Hz) to
upper 5% frequency
Entered: LK
Engineer: GJR
Sales: JC
Approved: BAM
Spec Number:
Date: 3/30/2017
Date: 3/30/2017
Date: 3/30/2017
Date: 3/30/2017
50208
3425 Walden Avenue, Depew, NY 14043
Phone: 716-684-0001
Fax: 716-684-0987
E-Mail: [email protected]