Page 51
SETTING FUNCTIONAL FEATURES
Std. by.
STAND BY [1001]
Idle time beyond which the instrument automatically assumes a low brightness status and keypad lock.
0 = deactivated function.
Values: from 0 to 999.
Default: 0
LoCk.
KEYPAD LOCK [1002]
Set of 4 binary values that correspond to the 4 keys.
0 —> key not locked
1—> key locked
(e.g. 0101 corresponds to locking the 2nd and 4th key).
Values from 0000 to 1111.
Default: 0000
P1n.Cod..
PASSWORD SETTING [1003]
If programmed, to access the programming menu you must enter the password. In the event of sub-
sequent accesses it is no longer necessary to type the password until the stand-by intervenes or the
instrument is powered off.
Values from 0 to 9999.
Default: 0000 (no Pasword)
PEAk.
PEAK FUNCTION [1004]
Allows the peak function to be available or not and refers it to the net or gross weight.
If the application does not provide this feature you can disable it.
Selectable setting:
NONE [0]
NET [1]
GROSS [2]
Default: NONE
Содержание DAT11
Страница 2: ...Page II ...
Страница 83: ...Page 81 ...