Operating data:
thermos 200 DC
thermos 300 DC
Power input:
11 to 64 W
11 to 145 W
Volumetric flow ranges:
50 to 250 m³/h
200 m³/h at 100 Pa
50 to 400 m³/h
380 m³/h at 100 Pa
Heat recovery rates:
1)
results may vary according to the
test methods used, e.g. whether
measured with or without
condensation, or whether on the
exhaust or supply air side
2)
best efficiencies in the German
market today
approx.. 97... 99 %
1)
acc. to DIBT: measured by VEW Energie AG Dortmund – supply air side)
92 %
1)2)
(effective: measured by Passivhaus Institute Darmstadt – exhaust air side)
Sound pressure level:
(3m distance, to DIN 45635
Part 1)
Vent. step 58%
Vent. step 100%
28 dB(A)
34 dB(A)
35 dB(A)
42 dB(A)
Kennlinie:
Important!
Characteristics may be different due to allowable tolerances (e.g. acc. to manufacturer: – fans 10%, transformers 5% admissible).
Operation: Operating
element (control unit):
Automatic control
Standard functions
•
8 independent time programs can be defined and assigned to any
day of the week
•
motorised summer bypass valve
•
manual stop in standby mode with limited power input below 2 W
•
manual adjustment of ventilation steps (off, minimum, normal,
maximum)
•
programmer can be installed in any place in the house
•
ventilation steps programmable in 1% increments (30-100% of
maximum fan power)
•
adjustable balance between supply and extract air fans
•
filter monitor for change interval
freeze protection for downstream hot water duct heater
Options
(with extra price for accessories)
•
Control of an electric valve at the ground to air heat exchanger (either
air intake through the ground to air heat exchanger or direct air
intake)
•
Control of a frost protection pre-heater (frost protection heater
prevents ice formation and thus replaces a ground to air heat
exchanger in winter)
•
Constant flow control (permanent monitoring and balancing of the
supply and extract air flows, fireplace compliant)
•
Control of a heating circuit (e.g. heating circuit pump or electric back-
up duct heater up to 2.1 kW) – also with night reduction
•
Several boost switches can be connected to the programmer
•
The MVHR unit can be operated by several programmers (e.g. one in
the place of installation, another one in the living room). If a duct
heater is used, the room temperature is recorded at the first
programmer.
Comfort control unit
(LxWxD in mm: 158x125x32)
Cable: IYSTY 2x2x0.6, max. 15 m, by
customer
The programmer can be installed in the living
area. Further programmers (option) and boost
switches (by customer) can be connected.
Содержание thermos 300 DC
Страница 2: ......
Страница 46: ......
Страница 47: ......
Страница 48: ......
Страница 52: ......
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 59: ......
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 66: ......