3. Load configuration
145
SmartNode 1000 and 2000 Series Getting Started Guide
10 • Getting Started with the SmartNode Device
172.16.1.99(if-ip)[eth0]#ping <IP Address of the host>
Respectively from the host: ping 172.16.1.99
Note
To ping outside your local LAN, you will need to configure the default gateway.
3. Load configuration
Download a configuration note to your PC from the support page of the Patton-Inalp web server
(http://www.inalp.ch/en/support/confignotes/), which matches your application. Adapt the configuration as
described in the configuration note to your network (do not forget to modify the IP address) and copy the
modified configuration to a TFTP server. The SmartNode can now load its configuration from this server.
In this example we assume the TFTP server on the host with the IP address 172.16.1.11 and the configuration
named SN.cfg in the root directory of the TFTP server.
172.16.1.99(if-ip)[eth0]#copy tftp://172.16.1.11/SN.cfg startup-config
Download...100%
172.16.1.99(if-ip)[eth0]#
After the SmartNode has been rebooted the new start up configuration will be activated.
172.16.1.99(if-ip)[eth0]#reload
Running configuration has been changed.
Do you want to copy the 'running-config' to the 'startup-config'?
Press 'yes' to store, 'no' to drop changes : no
Press 'yes' to restart, 'no' to cancel : yes
The system is going down
Bootloader
The bootloader ensures that basic operations, network access, and downloads are possible in case of interrupted
or corrupted application image downloads.
Start Bootloader and login
To start the Bootloader explicitly, power on the SmartNode while pressing the reset button. All front LEDs will
light up. Keep pressing the reset button until the BRI/Ethernet LEDs on SmartNode 1x00 and the ACT LED on
SmartNode 2x00 are off. When the bootloader starts, the BRI LEDs on SmartNode 1x00 and the ACT LED on
SmartNode 2x00 are blinking. Open a Telnet connection to the SmartNode via either one of Ethernet interfaces
and the Login display shown in
figure 90
will appear. Use the credentials admin/patton to login.
Note
The Bootloader does
not
support the console interface. The Ethernet inter-
faces preserve the IP addresses, IP masks, and default gateway that they had
before starting the bootloader.
Содержание 1000
Страница 12: ...Compliance Information SmartNode 1000 and 2000 Series Getting Started Guide 12 Compliance...
Страница 52: ...2 Product Overview SmartNode 1000 and 2000 Series Getting Started Guide 52...
Страница 62: ...3 Planning the installation SmartNode 1000 and 2000 Series Getting Started Guide 62...
Страница 68: ...3 Planning the installation SmartNode 1000 and 2000 Series Getting Started Guide 68 Where to go next...
Страница 70: ...4 SmartNode 1200 installation SmartNode 1000 and 2000 Series Getting Started Guide 70...
Страница 80: ...4 SmartNode 1200 installation SmartNode 1000 and 2000 Series Getting Started Guide 80 Connecting cables...
Страница 82: ...5 SmartNode 1400 installation SmartNode 1000 and 2000 Series Getting Started Guide 82...
Страница 92: ...6 SmartNode 2300 installation SmartNode 1000 and 2000 Series Getting Started Guide 92...
Страница 110: ...7 SmartNode 2400 installation SmartNode 1000 and 2000 Series Getting Started Guide 110...
Страница 124: ...7 SmartNode 2400 installation SmartNode 1000 and 2000 Series Getting Started Guide 124 Connecting cables...
Страница 126: ...8 Line power module installation SmartNode 1000 and 2000 Series Getting Started Guide 126...
Страница 134: ...9 Interface card installation SmartNode 1000 and 2000 Series Getting Started Guide 134...
Страница 138: ...9 Interface card installation SmartNode 1000 and 2000 Series Getting Started Guide 138 Installing interface cards...
Страница 140: ...10 Getting Started with the SmartNode Device SmartNode 1000 and 2000 Series Getting Started Guide 140...
Страница 151: ...151 Chapter 11 Monitoring Status Chapter contents Status LEDs 153...
Страница 152: ...11 Monitoring Status SmartNode 1000 and 2000 Series Getting Started Guide 152...
Страница 154: ...11 Monitoring Status SmartNode 1000 and 2000 Series Getting Started Guide 154 Status LEDs...
Страница 156: ...12 Contacting Patton for assistance SmartNode 1000 and 2000 Series Getting Started Guide 156...
Страница 160: ...A Specifications SmartNode 1000 and 2000 Series Getting Started Guide 160...
Страница 166: ...B Cabling SmartNode 1000 and 2000 Series Getting Started Guide 166...
Страница 172: ...B Cabling SmartNode 1000 and 2000 Series Getting Started Guide 172 BRI Figure 102 Connecting a BRI to an NT...
Страница 175: ...T1 PRI 175 SmartNode 1000 and 2000 Series Getting Started Guide B Cabling...
Страница 176: ...B Cabling SmartNode 1000 and 2000 Series Getting Started Guide 176 T1 PRI...
Страница 178: ...C Port pin outs SmartNode 1000 and 2000 Series Getting Started Guide 178...