DS0 Connection ID (DAX Connection ID) window
39
Model 6511RC Matrix Switch Administrators’ Reference Guide
5 • DS0 Mapping
H.110 Timeslots
Displays the H.110 timeslots.
DS0 Connection ID (DAX Connection ID) window
The DS0 Connection ID window provides the capability to delete an existing DS0 mapping (connection). The
page also displays all the mapping parameters which define the connection.
Viewing the DS0 Connection ID window
To view the DS0 Connection ID window for a certain DS0 mapping (connection):
1. On the DSO Mapping page, under Static Connections, find the Connection ID number for the DS0 map-
ping you wish to view.
2. Click the Connection ID number hyperlink to display the DS0 Connection ID window for the selected
connection ID.
Deleting a DS0 Mapping
To delete the DS0 Mapping displayed on the DS0 Connection ID window:
1. In the drop-down menu for the Connection Status parameter, ensure that the value delete(1) is selected.
2. Click the Submit Query button to delete the connection (DS0 mapping).
Содержание 6511RC
Страница 4: ...Summary Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 4...
Страница 8: ...Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 8...
Страница 12: ...Model 6511RC Matrix Switch Administrators Reference Guide 2...
Страница 16: ...About this guide Model 6511RC Matrix Switch Administrators Reference Guide 6...
Страница 20: ...1 Introduction Model 6511RC Matrix Switch Administrators Reference Guide 10 Saving HTTP HTML Object Changes...
Страница 38: ...4 Alarms Model 6511RC Matrix Switch Administrators Reference Guide 28 Alarms management windows...
Страница 80: ...8 IP 6511RC Matrix Switch Administrators Reference Guide 70 Address Translation Information window...
Страница 102: ...11 SNMP Model 6511RC Matrix Switch Administrators Reference Guide 92 SNMP window...
Страница 132: ...13 System Log Model 6511RC Matrix Switch Administrators Reference Guide 122 System Log Non Volatile Memory window...
Страница 142: ...14 E1 Link Model 6511RC Matrix Switch Administrators Reference Guide 132 SDH E1 test parameters...
Страница 158: ...15 SDH Model 6511RC Switch Matrix Administrators Reference Guide 148 SDH Configuration link...
Страница 159: ...149 Chapter 16 About Chapter contents Introduction 150 Patton Electronics Company contact information 150...
Страница 164: ...17 License Model 6511RC Matrix Switch Administrators Reference Guide 154 End User License Agreement...
Страница 165: ...155 Appendix A Updating the operating software Chapter contents Introduction 156 Software upgrade procedures 156...