Near End Line Statistics—History
127
Model 6511RC Matrix Switch Administrators’ Reference Guide
14 • E1 Link
DMs (degraded minutes) (dsx1CurrentDMs)
The number of degraded minutes (DMs) encountered by a DS1 interface in the current 15-minute interval.
LCVs (line code violations) (dsx1CurrentLCVs)
The number of line code violations (LCVs) encountered by a DS1 interface in the current 15-minute interval.
Near End Line Statistics—History
Click on Near End Line Statistics—History (see
figure 63
on page 125) (orange diamond) to display line statis-
tics for prior completed 15-minute intervals within the last 24 hours (see
figure 65
). This does not include the
current 15-minute interval.
Figure 65. History of Near End Performance window
INT (interval) (dsx1IntervalNumber)
A number between 1 and 96, where 1 is the most recently completed 15-minute interval and 96 is the least
recently completed 15-minutes interval. When all 96 intervals are visible, then the 6511RC has been operating
(powered-on) for at least 24 hours. If less than 96 intervals are visible, then it has been less than 24 hours since
the 6511RC was powered up.
ESs (errored seconds) (dsx1intervaless)
The number of errored seconds encountered by a DS1 interface in one of the previous 96, 15-minute intervals.
SESs (severely errored seconds) (dsx1IntervalSESs)
The number of severely errored seconds encountered by a DS1 interface in one of the previous 96, 15-
minute intervals.
SEFSs (severely errored frame seconds) (dsx1IntervalSEFSs)
The number of severely errored framing seconds encountered by a DS1 interface in one of the previous 96,
15-minute intervals.
UASs (unavailable seconds) (dsx1IntervalUASs)
The number of unavailable seconds encountered by a DS1 interface in one of the previous 96, 15-minute intervals.
CSSs (controlled slip seconds) (dsx1IntervalCSSs)
The number of controlled slip seconds encountered by a DS1 interface in one of the previous 96, 15-
minute intervals.
Содержание 6511RC
Страница 4: ...Summary Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 4...
Страница 8: ...Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 8...
Страница 12: ...Model 6511RC Matrix Switch Administrators Reference Guide 2...
Страница 16: ...About this guide Model 6511RC Matrix Switch Administrators Reference Guide 6...
Страница 20: ...1 Introduction Model 6511RC Matrix Switch Administrators Reference Guide 10 Saving HTTP HTML Object Changes...
Страница 38: ...4 Alarms Model 6511RC Matrix Switch Administrators Reference Guide 28 Alarms management windows...
Страница 80: ...8 IP 6511RC Matrix Switch Administrators Reference Guide 70 Address Translation Information window...
Страница 102: ...11 SNMP Model 6511RC Matrix Switch Administrators Reference Guide 92 SNMP window...
Страница 132: ...13 System Log Model 6511RC Matrix Switch Administrators Reference Guide 122 System Log Non Volatile Memory window...
Страница 142: ...14 E1 Link Model 6511RC Matrix Switch Administrators Reference Guide 132 SDH E1 test parameters...
Страница 158: ...15 SDH Model 6511RC Switch Matrix Administrators Reference Guide 148 SDH Configuration link...
Страница 159: ...149 Chapter 16 About Chapter contents Introduction 150 Patton Electronics Company contact information 150...
Страница 164: ...17 License Model 6511RC Matrix Switch Administrators Reference Guide 154 End User License Agreement...
Страница 165: ...155 Appendix A Updating the operating software Chapter contents Introduction 156 Software upgrade procedures 156...