SYSTEM LOG (configuration) window
119
Model 6511RC Matrix Switch Administrators’ Reference Guide
13 • System Log
•
priorityDebug(10)
•
priorityInfo(20)
•
priorityOddity(40)
•
priorityService(60)
•
prioritySystem(80)
•
priorityDisable(1000)
Min Priority for RAM (SyslogTablePriority)
System messages which have a priority equal to or greater than this setting will appear in System Log—Volatile
Memory. The lower the number next to the priority listed below, the more details system logging will provide.
Selecting priorityVerbose will generate the most messages, while selecting priorityDisable will turn off all messages.
•
priorityVerbose(5)
•
priorityDebug(10)
•
priorityInfo(20)
•
priorityOddity(40)
•
priorityService(60)
•
prioritySystem(80)
•
priorityDisable(1000)
Unix Facility (syslogUnixFacility)
This setting is used when syslog messages are sent to a Unix-type syslog daemon. In this case the message will
include the facility and priority coding.
Call Trace (syslogCallTrace)
Enabling this will activate the call tracing utility. This is a powerful debugging utility which will log every sin-
gle function call and return. At the death of a box the call trace will be printed out and can be sent to tech sup-
port. This utility will take a large amount of CPU power.
•
disable(0)—Disable function call tracing.
•
enable(1)—Enable function call tracing.
•
dump(2)—Display function call tracing on the computer monitor.
•
disable(0)
•
user(1)
•
mail(2)
•
daemon(3)
•
auth(4)
•
syslog(5)
•
lpr(6)
•
news(7)
•
uucp(8)
•
cron(9)
•
authpriv(10)
•
ftp(11)
•
local0(16)
•
local1(17)
•
local2(18)
•
local3(19)
•
local4(20)
•
local5(21)
•
local6(22)
•
local7(23)
Содержание 6511RC
Страница 4: ...Summary Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 4...
Страница 8: ...Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 8...
Страница 12: ...Model 6511RC Matrix Switch Administrators Reference Guide 2...
Страница 16: ...About this guide Model 6511RC Matrix Switch Administrators Reference Guide 6...
Страница 20: ...1 Introduction Model 6511RC Matrix Switch Administrators Reference Guide 10 Saving HTTP HTML Object Changes...
Страница 38: ...4 Alarms Model 6511RC Matrix Switch Administrators Reference Guide 28 Alarms management windows...
Страница 80: ...8 IP 6511RC Matrix Switch Administrators Reference Guide 70 Address Translation Information window...
Страница 102: ...11 SNMP Model 6511RC Matrix Switch Administrators Reference Guide 92 SNMP window...
Страница 132: ...13 System Log Model 6511RC Matrix Switch Administrators Reference Guide 122 System Log Non Volatile Memory window...
Страница 142: ...14 E1 Link Model 6511RC Matrix Switch Administrators Reference Guide 132 SDH E1 test parameters...
Страница 158: ...15 SDH Model 6511RC Switch Matrix Administrators Reference Guide 148 SDH Configuration link...
Страница 159: ...149 Chapter 16 About Chapter contents Introduction 150 Patton Electronics Company contact information 150...
Страница 164: ...17 License Model 6511RC Matrix Switch Administrators Reference Guide 154 End User License Agreement...
Страница 165: ...155 Appendix A Updating the operating software Chapter contents Introduction 156 Software upgrade procedures 156...