28

Off

The NetLink-T1™ is in remote loopback mode or sending
a pattern.  Local loopback is disabled.

LocP

The NetLink-T1™ is in Local Loopback mode, and is
sending a test pattern.

Remote Loop Idle  

(default)

The Remote Digital Loopback (RDL) test checks the performance

of both the local and remote NetLink-T1™s, as well as the communica-
tion link between them. Data from the local DTE is sent across the
entire communication circuit and looped back to the local DTE.    

The NetLink-T1™ Initiating a RL can be in one of the following

states:  

Idle

No user-controlled loopbacks are active.

TxPr

The NetLink-T1™ is sending the preparatory phase pat-
tern lasting for approximately 2 -5 seconds.

WtAk

The NetLink-T1™ is waiting for an acknowledgement
from the remote unit.  If the remote unit does not
respond, the WtAk message will remain on the screen.

RxAk

The NetLink-T1™ has received an acknowledgement
from the remote unit.

Tout

The NetLink-T1™ is waiting before entering the Remote 
Loopback test mode.

TM

The NetLink-T1™ has successfully negotiated the Remote
Loopback test and is in control of the remote unit.  You
may send a test pattern at this point by pressing:

c <spacebar>

TxTr

The NetLink-T1™ is sending a Terminate Loopback mes-
sage to the remote unit.  If the remote unit does not
respond, the local unit will return to the Idle state.

Tx1s

If the remote NetLink-T1™ responds to the local NetLink-
T1™’s terminate loopback request, the local unit then
sends an all ones pattern before returning to the Idle state

TxP

The NetLink-T1™ is sending a test pattern while in Test
Mode

TxUp

The NetLink-T1 is sending the Loop-Up command to initi-
ate a CSU loopback

TxDN

The NetLink-T1 is sending the LoopDown command to
terminate a CSU loopback.

IdlP

The NetLink-T1™ is sending a test pattern in place of
data.  The NetLink-T1™ is not in test mode.

The NetLink-T1™ receiving a RL can be in one of the following states:  

RxPr

The NetLink-T1™ is receiving a preparatory pattern.

Sack

The NetLink-T1™, upon receiving a preparatory pattern,
sends an acknowledgement message.

RL

The NetLink-T1™ is in remote loopback mode.  

RxTr

The NetLink-T1™ is receiving a terminate loopback mes-
sage.  

Wt1s

The NetLink-T1™ is waiting for a sequence of all ones
and will time out if it does not receive it. 

IdleP

The NetLink-T1™ is sending a QRSS, 511 or 2047 pattern.

Off

The NetLink-T1™ is in local loopback.

RDL Type:  V.54 

(default)

The user can set this variable to select the type of remote loop that will
be initiated by the NetLink-T1.  If set to V.54, the NetLink-T1 will initiate
a V.54 loop when Remote Loop is selected either by software or the
front panel switches.  If set to CSU, the NetLink-T1 will initiate a CSU
loop when Remote Loop is selected either by software or the front
panel switches.  

NOTE:  The NetLink will always respond to both loop types if they
are enabled as described in Section 3.2.2 System Configuration.

Test Pattern  Idle 

(default)

Options:  Idle or Sending

To send a pattern, press the ‘c’ key and press <spacebar> to send

the test pattern. The “OK” message indicates the received test pattern
is error-free. The “BE” message indicates errors in the received pat-
tern.            

27

b

c

d

Содержание 2710RC Series

Страница 1: ...______________________________________ __________________________________________ __________________________________________ __________________________________________ ________________________________...

Страница 2: ...product fails or does not perform as warranted your sole recourse shall be repair or replacement as described above Under no condition shall Patton Electronics be liable for any damages incurred by t...

Страница 3: ...ance with FCC rules and regulation CFR 47 68 218 b 6 you must notify the telephone company prior to disconnection The following information may be required when applying to your local telephone compan...

Страница 4: ...rols The Netlink T1 supports D4 ESF framing options and AMI B8ZS B7ZS line coding Netlink T1 also supports a full range of system and diagnostic features that make system setup easy The NetLink T1 pro...

Страница 5: ...aming bits are now used for framing CRC and the Facility Data Link FDL The FDL allows maintenance messages and information to be passed between the 2710RC and the Central Office Line Coding Options Al...

Страница 6: ...with your DTE equip ment for more information on its operation In most cases when there are errors on the line only in the direction of the transmit data either S2 2 or S2 3 can be changed to solve t...

Страница 7: ...CM12548C Strap Settings Figure 5 shows strap locations for the Model 1001RCM12548C DB 25 rear cards These straps determine various grounding charac teristics for the terminal interface and twisted pai...

Страница 8: ...onnected position this strap links M 34 pin A frame ground In the open position pin A is disconnected from frame ground JB3 Position 1 2 DTE Shield Pin A and FRGND Connected Position 2 3 DTE Shield Pi...

Страница 9: ...is described below For more information on the Model 1001CC please refer to the Model 1001CC user manual 3 3 1 Setting the Card Address The 2710RC contains two rotary switches S3 and S4 which are use...

Страница 10: ...ter Carriage Return key The password prompt will be displayed as shown below 6 Note The password is case sensitive Type the password and press Enter The factory default password for the unit is patton...

Страница 11: ...to permanent memory Logoff For security log off the control menu by executing the Logoff command This will blank the screen until an Enter key is pressed 3 3 4 System Configuration The default System...

Страница 12: ...sity This is the most acceptable way to accomplish 64 kb s on each DS0 channel B7ZS This stands for Bipolar Seven Zero Substitution Instead of introducing bipolar violations this method substitutes a...

Страница 13: ...default Options Enabled Disabled The ESF format provides the CO the ability to put the customer installation s NetLink T1 into loopback mode The NetLink T1 rec ognizes these special messages that are...

Страница 14: ...S0 Channel Rate is 56kbps the Bandwidth Selected will be a multiple of 56k not of 64k When using the DIP switches to set the band width the starting channel is always channel 1 Front Panel Switches En...

Страница 15: ...e returning to the Idle state TxP The NetLink T1 is sending a test pattern while in Test Mode TxUp The NetLink T1 is sending the Loop Up command to initi ate a CSU loopback TxDN The NetLink T1 is send...

Страница 16: ...ng error exceeds a certain threshold of errors This may happen due to a disconnected line an extremely noisy connection or mismatched framing Loss of Sync LOS occurs when the T1 framer in the unit can...

Страница 17: ...1 and 2 are provided for easy identification of your unit after installation You may want to give each unit a unique name via the header lines to help distinguish one unit from another You can enter a...

Страница 18: ...factory default configuration except for the header lines and the password by executing the Set to Default Configuration command Service Information If you need to contact us for help you can view the...

Страница 19: ...ual AC and DC Rack Mount Power Supplies for fuse and power card replacement information 4 2 INSTALLING THE INTERFACE DRIVER BOARD The DTE electrical interface on the 2710RC is determined by a DTE daug...

Страница 20: ...r host computer When making the connection to your DTE device use a straight through cable of the shortest possible length we recommend 6 feet or less When purchasing or constructing an interface cabl...

Страница 21: ...os controlled slips severe errors or bit errors when sending V 52 test patterns When sending a test pattern the LED will remain lit if the unit does not receive the identical pattern When it receives...

Страница 22: ...L test follow these steps 1 Activate RDL This may be done in three ways a Enter Remote Loop from the System 42 Diagnostics Statistics menu and toggle the Spacebar until RL appears next to the Remote L...

Страница 23: ...AT E Test Pattern with Error Injection 44 APPENDIX A PATTON NETLINK T1 MODEL 2710RC SPECIFICATIONS WAN Speed 1 544 Mbps WAN Connection RJ 48C Nominal Impedance 100 Ohms DTE Interface EIA 530 ITU T V 3...

Страница 24: ...35 Interface with M 34F RJ48C Rear Card 1001RPEM RAC 120 240V Rear Power Entry Module 1001RPEM RAC 120 240V Rear Power Entry Module 1001RPSM RUI 120 240V Front Power Supply Module 1001RPEM RDC DC Rea...

Страница 25: ...nd Shield B SGND Signal Ground D CTS DCE Source E DSR DCE Source Always On F CD DCE Source L LL Local Loop DTE Source M TM Test Mode Indicator DCE Source N RL Remote Loop DTE Source P TD Transmit Data...

Страница 26: ...A DTE Source 15 TC Transmitter Clock B DCE Source 16 RD Receive Data A DCE Source 17 RC Receiver Clock A DCE Source 18 LL Local LIne Loop 19 RTS Request to Send B DTE Source 20 DTR Data Terminal Ready...

Отзывы: