Idle 

Indicates that  NetLink-T1™ is not sending a pattern.

Sending Indicates that NetLink-T1™ is sending a pattern. 

Error Insertion  Off 

(default)

Options:  On, Off

You may inject intentional errors into the test pattern by turning

Error Insertion ON.  The Error (ERR) LED will blink once per second.

Selected Pattern

Options:  QRSS, 511, or  2047

Use this option to select the test pattern used to test the link.

NI STATUS
The Network interface (NI) status is shown in
the middle of the Diagnostics/Statistics
screen. The brackets are empty when the
link is operating normally. In this example,
various two or three-letter messages are dis-
played within the brackets, illustrating what
you may see if the NetLink-T1™ is not con-
nected at all or is in a loss of signal condi-
tion. Here are the eight status messages.

Excessive zeros [EXZ], i.e., lack of pulses, detected. This condition
may occur if the unit is not connected to the network, in which case the
EXZ is displayed continuously. If EXZ comes on intermittently, there
may be a frame, line code or data rate mismatch between the near and
far-end units.

Receiver Carrier Loss [RCL]  occurs when 192 consecutive zeros
have been detected at the network interface. RCL clears when a pulse
is detected.

Frame Bit Error [FE]  occurs when there is an error in the framing bit
sequence. This may happen due to a disconnected line, mismatched
framing formats or severe errors in the data stream. This error may
indicate a noisy line or cable condition.  This error may indicate a noisy
line or cable connection if the frames appear to be set correctly. 

Severe Frame Error [SE]  occurs when the framing error exceeds a
certain threshold of errors. This may happen due to a disconnected
line, an extremely noisy connection, or mismatched framing.

Loss of Sync [LOS]  occurs when the T1 framer in the unit cannot
synchronize itself to the received data stream. This may happen due to
a disconnected line.

Out of Frame [OOF] occurs when no valid frame structure can be
found. This may happen due to a disconnected line or mismatched
framing or mismatched framing.

Alarm Indication Signal [AIS]  indicates that the remote unit or the
central office is sending a Blue Alarm, because it is not receiving a sig-
nal; the alarm is an unframed all-ones signal, mainly used to keep the
line alive and to indicate that it is not receiving any signal. This may
indicate that the local unit is receiving a good signal, but that the trans-
mit link may be broken.

Receive Alarm Indication [RAI]  indicates that the local unit is receiv-
ing a Yellow Alarm. This alarm is sent by the remote unit or the central
office when it loses the received signal. This indicates the local unit’s
transmitted signal is not reaching the remote unit.

Rx Level  The Model 2710RC displays the current received signal
strength in dB. There are four level ranges detected:

+2 to –7.5
-7.5 to –15
-15 to –22.5
< -22.5

Valid Interval Count & Current Interval Time

The Valid Interval Count and Current Interval Time display the

number of valid 15 minute intervals in the last 24 hours and the num-
ber of seconds which have elapsed in the current interval, respectively.
The Valid Interval Count saturates at the count of 96 (96 * 15min = 24
hours), while the Current Interval Time rolls over after 900 counts.
When the counter rolls over, it is reset to zero, and the Interval Counter
is incremented by one if the count is less than 96.

e

f

Valid Interval Count:   [96]
Current Interval Time: [899]

Содержание 2710RC Series

Страница 1: ...______________________________________ __________________________________________ __________________________________________ __________________________________________ ________________________________...

Страница 2: ...product fails or does not perform as warranted your sole recourse shall be repair or replacement as described above Under no condition shall Patton Electronics be liable for any damages incurred by t...

Страница 3: ...ance with FCC rules and regulation CFR 47 68 218 b 6 you must notify the telephone company prior to disconnection The following information may be required when applying to your local telephone compan...

Страница 4: ...rols The Netlink T1 supports D4 ESF framing options and AMI B8ZS B7ZS line coding Netlink T1 also supports a full range of system and diagnostic features that make system setup easy The NetLink T1 pro...

Страница 5: ...aming bits are now used for framing CRC and the Facility Data Link FDL The FDL allows maintenance messages and information to be passed between the 2710RC and the Central Office Line Coding Options Al...

Страница 6: ...with your DTE equip ment for more information on its operation In most cases when there are errors on the line only in the direction of the transmit data either S2 2 or S2 3 can be changed to solve t...

Страница 7: ...CM12548C Strap Settings Figure 5 shows strap locations for the Model 1001RCM12548C DB 25 rear cards These straps determine various grounding charac teristics for the terminal interface and twisted pai...

Страница 8: ...onnected position this strap links M 34 pin A frame ground In the open position pin A is disconnected from frame ground JB3 Position 1 2 DTE Shield Pin A and FRGND Connected Position 2 3 DTE Shield Pi...

Страница 9: ...is described below For more information on the Model 1001CC please refer to the Model 1001CC user manual 3 3 1 Setting the Card Address The 2710RC contains two rotary switches S3 and S4 which are use...

Страница 10: ...ter Carriage Return key The password prompt will be displayed as shown below 6 Note The password is case sensitive Type the password and press Enter The factory default password for the unit is patton...

Страница 11: ...to permanent memory Logoff For security log off the control menu by executing the Logoff command This will blank the screen until an Enter key is pressed 3 3 4 System Configuration The default System...

Страница 12: ...sity This is the most acceptable way to accomplish 64 kb s on each DS0 channel B7ZS This stands for Bipolar Seven Zero Substitution Instead of introducing bipolar violations this method substitutes a...

Страница 13: ...default Options Enabled Disabled The ESF format provides the CO the ability to put the customer installation s NetLink T1 into loopback mode The NetLink T1 rec ognizes these special messages that are...

Страница 14: ...S0 Channel Rate is 56kbps the Bandwidth Selected will be a multiple of 56k not of 64k When using the DIP switches to set the band width the starting channel is always channel 1 Front Panel Switches En...

Страница 15: ...e returning to the Idle state TxP The NetLink T1 is sending a test pattern while in Test Mode TxUp The NetLink T1 is sending the Loop Up command to initi ate a CSU loopback TxDN The NetLink T1 is send...

Страница 16: ...ng error exceeds a certain threshold of errors This may happen due to a disconnected line an extremely noisy connection or mismatched framing Loss of Sync LOS occurs when the T1 framer in the unit can...

Страница 17: ...1 and 2 are provided for easy identification of your unit after installation You may want to give each unit a unique name via the header lines to help distinguish one unit from another You can enter a...

Страница 18: ...factory default configuration except for the header lines and the password by executing the Set to Default Configuration command Service Information If you need to contact us for help you can view the...

Страница 19: ...ual AC and DC Rack Mount Power Supplies for fuse and power card replacement information 4 2 INSTALLING THE INTERFACE DRIVER BOARD The DTE electrical interface on the 2710RC is determined by a DTE daug...

Страница 20: ...r host computer When making the connection to your DTE device use a straight through cable of the shortest possible length we recommend 6 feet or less When purchasing or constructing an interface cabl...

Страница 21: ...os controlled slips severe errors or bit errors when sending V 52 test patterns When sending a test pattern the LED will remain lit if the unit does not receive the identical pattern When it receives...

Страница 22: ...L test follow these steps 1 Activate RDL This may be done in three ways a Enter Remote Loop from the System 42 Diagnostics Statistics menu and toggle the Spacebar until RL appears next to the Remote L...

Страница 23: ...AT E Test Pattern with Error Injection 44 APPENDIX A PATTON NETLINK T1 MODEL 2710RC SPECIFICATIONS WAN Speed 1 544 Mbps WAN Connection RJ 48C Nominal Impedance 100 Ohms DTE Interface EIA 530 ITU T V 3...

Страница 24: ...35 Interface with M 34F RJ48C Rear Card 1001RPEM RAC 120 240V Rear Power Entry Module 1001RPEM RAC 120 240V Rear Power Entry Module 1001RPSM RUI 120 240V Front Power Supply Module 1001RPEM RDC DC Rea...

Страница 25: ...nd Shield B SGND Signal Ground D CTS DCE Source E DSR DCE Source Always On F CD DCE Source L LL Local Loop DTE Source M TM Test Mode Indicator DCE Source N RL Remote Loop DTE Source P TD Transmit Data...

Страница 26: ...A DTE Source 15 TC Transmitter Clock B DCE Source 16 RD Receive Data A DCE Source 17 RC Receiver Clock A DCE Source 18 LL Local LIne Loop 19 RTS Request to Send B DTE Source 20 DTR Data Terminal Ready...

Отзывы: