Summary of Contents for JPM083A

Page 1: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 1998 Black Box Corporation All rights reserved ...

Page 2: ...ll 724 746 5500 or fax 724 746 0746 Mail order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com CUSTOMER SUPPORT INFORMATION JULY 1998 JPM083A JPM084A JPM085A JPM086A 12 Port Modular Patch Panels 24 Port Modular Patch Panels 24 PORT MODULAR PATCH PANEL 6 12 18 24 CATEGORY 5 ...

Page 3: ...R PATCH PANELS TRADEMARKS USED IN THIS MANUAL UL is a registered trademark of Underwriters Laboratories Incorporated Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners ...

Page 4: ...andwidth Support Up to 100 MHz Transmission Exceeds Category 5 requirements for near end crosstalk NEXT attenuation and return loss as specified in TSB 40 standard MTBF 200 cycles Temperature Operating 14 to 140 F 10 to 60 C Storage 40 to 158 F 40 to 70 C 70 relative humidity Size JPM083A JPM084A 4 2 H x 17 8 W x 2 8 D 10 7 x 45 2 x 7 1 cm JPM085A JPM086A 8 2 H x 17 8 W x 2 8 D 20 8 x 45 2 x 7 1 c...

Page 5: ...enuation and return loss 2 2 Features The panel s simple one piece design plus cover guarantees a clean installation even in small closets Removable cover protects terminations Total front access to the 110 clips and modular jacks separate fields for terminating and cross connecting cuts installation time and labor costs The Patch Panel is clearly labeled with jack and block identification numbers...

Page 6: ...3 18 19 24 1 6 7 12 13 18 19 24 5 Category 5 Category Removable cover protects terminations Separate fields for terminating patching Removable unobstructed designation strips Built in jumper management Built in wire management helps eliminate cable stress maintain proper bend radius Silk screened jack and block identification ...

Page 7: ...panel and 2 the suggested routing of line cords between panels This setup organizes the cables so the 110 clips and RJ 45 jacks are easily accessible even with a full patch panel Since NEXT electrical performance is affected by wiring practices the TIA EIA in 568 specifies preserving wiring twist as closely as possible to the point of mechanical termination In addition TSB 40 states the amount of ...

Page 8: ...tion for the 24 Port Patch Panels J 7 J 12 J 13 J 18 J 19 J 24 J 1 J 6 1 6 7 12 13 18 19 24 J 7 J 12 J 13 J 18 J 19 J 24 J 1 J 6 1 6 7 12 13 18 19 24 23 19 15 11 7 3 21 17 13 9 5 1 22 18 14 10 6 2 24 20 16 12 8 4 8 27 2 00 3 84 14 31 15 63 17 75 3 84 5 Category 5 Category ...

Page 9: ...d Cable Installation for the 12 Port Patch Panels J 1 J 16 J 7 J 12 7 12 1 6 12 10 8 6 4 2 11 9 7 5 3 1 The numbers in the diagram below illustrate the suggested order to terminate 110 clips The illustration below shows the suggested routing for line cords ...