1.0  WARRANTY INFORMATION 

Patton Electronics warrants all Model 1004A components to be

free from defects, and will—at our option—repair or replace the product
should it fail within one year from the first date of shipment.

This warranty is limited to defects in workmanship or materials, and

does not cover customer damage, abuse or unauthorized modification.
If this product fails or does not perform as warranted, your sole
recourse shall be repair or replacement as described above.  Under no
condition shall Patton Electronics be liable for any damages incurred
by the use of this product.  These damages include, but are not limited
to, the following:  lost profits, lost savings and incidental or
consequential damages arising from the use of or inability to use this
product.  Patton Electronics specifically disclaims all other warranties,
expressed or implied, and the installation or use of this product shall be
deemed an acceptance of these terms by the user. 

1.1  RADIO AND TV INTERFERENCE

The Model 1004A generates and uses radio frequency energy, and

if not installed and used properly—that is, in strict accordance with the
manufacturer's instructions—may cause interference to radio and
television reception.  The Model 1004A has been tested and found to
comply with the limits for a Class A computing device in accordance
with the specifications in Subpart J of Part 15 of FCC rules, which are
designed to provide reasonable protection from such interference in a
commercial installation.  However, there is no guarantee that
interference will not occur in a particular installation.  If the Model
1004A does cause interference to radio or television reception, which
can be determined by disconnecting the RS-232 interface, the user is
encouraged to try to correct the interference by one or more of the
following measures:  moving the computing equipment away from the
receiver, re-orienting the receiving antenna and/or plugging the
receiving equipment into a different AC outlet (such that the computing
equipment and receiver are on different branches).

1.2 CE NOTICE

The CE symbol on your Patton Electronics equipment indicates

that it is in compliance with the Electromagnetic Compatibility (EMC)
directive and the Low Voltage Directive (LVD) of the Union European
(EU).  A Certificate of Compliance is available by contacting Technical
Support.

1

1.3 SERVICE

All warranty and non-warranty repairs must be returned freight

prepaid and insured to Patton Electronics.  All returns must have a
Return Materials Authorization number on the outside of the shipping
container.  This number may be obtained from Patton Electronics
Technical Service: (301) 975-1007, http://www.patton.com;
[email protected].  

Packages received without an RMA number

will not be accepted.

Patton Electronics’ technical staff is also available to answer any

questions that might arise concerning the installation or use of your
Model 1004A.  Technical Service hours:  8AM to 5PM EST, Monday
through Friday.

2

Содержание 1004A

Страница 1: ...manufacture products for your unique needs We would like to hear from you Please contact us in any of the following ways to tell us how you like this product and how we can meet your product needs to...

Страница 2: ...rules which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installatio...

Страница 3: ...data rates 1 2 Kbps 19 AWG twisted pair The Model 1004A can handle up to 50 terminal drops in a multipoint polling environment For RS 485 and serial printer applications requiring hardware handshakin...

Страница 4: ...ction If you have additional questions contact Technical Support at 301 975 1000 Note Switches S1 1 S1 2 should be switched simultaneously Switches S1 7 S1 8 should also be switched simultaneously S1...

Страница 5: ...the impedance of the input receiver You may select either a low impedance of 120 Ohms or a high impedance of 16 kOhms By selecting the proper impedance for each drop there may be up to 50 receivers i...

Страница 6: ...you to connect one or two pairs of bare wires to the Model 1004A you will need to open the case to access the terminal blocks The following instructions will tell you how to open the case connect the...

Страница 7: ...ct our technical support We have strain relief assemblies to accommodate most cable diameters RCV G XMT RCV G XMT 10 Insert the strain relief assembly and wire into the slot in the bottom half of the...

Страница 8: ...nnection to ground is optional RJ 45 Cable 4 Wire SIGNAL PIN PIN SIGNAL GND 2 7 GND RCV 3 5 XMT XMT 4 6 RCV XMT 5 3 RCV RCV 6 4 XMT GND 7 2 GND RJ 11 Cable 2 Wire SIGNAL PIN PIN SIGNAL XMT 3 3 XMT XMT...

Страница 9: ...ver cable wiring instructions and straight through cables between the slaves 4 3 CONNECTION TO THE RS 232 INTERFACE Once you have properly configured the Model 1004A and connected the twisted pair wir...

Страница 10: ...0W power dissipation at 1 mS Power Draws operating power from RS 232 data and control signals no AC power or batteries required Temperature 0 to 50 C Humidity 5 to 95 non condensing Size 2 66 x 2 10 x...