manualshive.com logo in svg
background image

3.4  CONFIGURATION SWITCH APPLICATIONS

The switch settings 

generally needed to configure the Model

1004A for various applications are shown in the table below.  Note: Do
not change switch settings until you have 

carefully read Section 3.3.

The setting for switch S1-4 determines whether the Model 1004A

echoes data back to the transmitting device (half-duplex mode only).

S1-4

Setting

On

Echo On

Off

Echo Off 

S1-5:  Carrier Control Method

The setting for switch S1-5 determines whether the carrier is

“Constantly On” or “Controlled by RTS”.  This setting allows for
operation in switched carrier, multipoint and/or hardware handshaking
applications.

S1-5

Setting

On

Controlled by RTS

Off

Constantly On

S1-6:  Receive Impedance

The setting for switch S1-6 selects the impedance of the input

receiver.  You may select either a “low” impedance of 120 Ohms or a
“high” impedance of 16 kOhms.  By selecting the proper impedance for
each drop, there may be up to 50 receivers in one application.

S1-6

Setting

On

Low (120 Ohm)

Off

High (16 kOhm typical)

S1-7 and S1-8:  2-Wire/4-Wire Modes

Switches S1-7 and S1-8 are set together to determine whether the

Model 1004A is in 2-wire or 4-wire operating mode.  Note: 2-wire mode
is half-duplex only.

S1-7

S1-8

Setting

On

On

2-wire mode

Off

Off

4-wire mode

7

8

S1-1:  “Xmt Off” Imp.  

OFF

OFF

OFF

OFF

OFF

S1-2:  “Xmt Off” Imp.

OFF

OFF

OFF

OFF

OFF

S1-3:  RTS/CTS Delay

ON

ON

ON

OFF

ON

S1-4:  Echo

OFF

OFF

OFF

OFF

OFF

S1-5:  Carrier Control

OFF

ON

ON

Master-OFF

ON

Slaves-ON      

S1-6:  Rcv Impedance

ON

ON

ON

Master - ON

Slaves - OFF

Last Slave - ON

S1-7:  2-wire/4-wire  

OFF

OFF

ON

OFF

ON

S1-8:  2-wire/4-wire  

OFF

OFF

ON

OFF

ON

TYPICAL MODEL 1004A APPLICATIONS

Point-to-Point

Switch

Settings

Multi-point

4W

2W

4W

2W

4W HDX

Содержание 1004A

Страница 1: ...manufacture products for your unique needs We would like to hear from you Please contact us in any of the following ways to tell us how you like this product and how we can meet your product needs to...

Страница 2: ...rules which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installatio...

Страница 3: ...data rates 1 2 Kbps 19 AWG twisted pair The Model 1004A can handle up to 50 terminal drops in a multipoint polling environment For RS 485 and serial printer applications requiring hardware handshakin...

Страница 4: ...ction If you have additional questions contact Technical Support at 301 975 1000 Note Switches S1 1 S1 2 should be switched simultaneously Switches S1 7 S1 8 should also be switched simultaneously S1...

Страница 5: ...the impedance of the input receiver You may select either a low impedance of 120 Ohms or a high impedance of 16 kOhms By selecting the proper impedance for each drop there may be up to 50 receivers i...

Страница 6: ...you to connect one or two pairs of bare wires to the Model 1004A you will need to open the case to access the terminal blocks The following instructions will tell you how to open the case connect the...

Страница 7: ...ct our technical support We have strain relief assemblies to accommodate most cable diameters RCV G XMT RCV G XMT 10 Insert the strain relief assembly and wire into the slot in the bottom half of the...

Страница 8: ...nnection to ground is optional RJ 45 Cable 4 Wire SIGNAL PIN PIN SIGNAL GND 2 7 GND RCV 3 5 XMT XMT 4 6 RCV XMT 5 3 RCV RCV 6 4 XMT GND 7 2 GND RJ 11 Cable 2 Wire SIGNAL PIN PIN SIGNAL XMT 3 3 XMT XMT...

Страница 9: ...ver cable wiring instructions and straight through cables between the slaves 4 3 CONNECTION TO THE RS 232 INTERFACE Once you have properly configured the Model 1004A and connected the twisted pair wir...

Страница 10: ...0W power dissipation at 1 mS Power Draws operating power from RS 232 data and control signals no AC power or batteries required Temperature 0 to 50 C Humidity 5 to 95 non condensing Size 2 66 x 2 10 x...