4.0  INSTALLATION

Once the Model 1004A is properly configured, it is ready to

connect to your system.  This section tells you how to properly connect
the Model 1004A to the twisted pair and RS-232 interfaces, and how to
operate the Model 1004A.

4.1  TWISTED PAIR CONNECTION

The Model 1004A supports point-to-point or multipoint

communication over one or two twisted pair.  There are two essential
requirements for installing the Model 1004A:   

1.

These units work in 

pairs.  Therefore, you must have one Model

1004A at each end of a one or two twisted pair interface.  In
multipoint environments, there must be one Model 1004A at the
RS-232 host and one at each RS-232 terminal.

2.

To function properly, the Model 1004A needs one or two twisted
pair of metallic wire.  These pairs must be 

unconditioned dry

metallic wire, between 19 and 26 AWG (the higher number gauges
may limit distance).  Standard dial-up telephone circuits, or leased
circuits that run through signal equalization equipment, are 

not

acceptable.

For your convenience, the Model 1004A is available with several

different twisted pair interfaces:  RJ-11 jack, RJ-45 jack, terminal blocks
with strain relief and dual modular jacks (for multipoint daisy-chaining).

4.1.1  TWISTED PAIR CONNECTION USING TERMINAL BLOCKS

If your application requires you to connect one or two pairs of bare

wires to the Model 1004A, you will need to open the case to access the
terminal blocks.  The following instructions will tell you how to open the
case, connect the bare wires to the terminal blocks and fasten the
strain relief collar in place so the wires won't pull loose.

1.  You should already have the case open for the configuration

procedure.  If not, see Section 3.2.   

2.  Strip the outer insulation from the twisted pair(s) about one inch

from the end.  

3.  Strip the insulation on each of the twisted pair wires about .25”.

4.  In a two pair circuit, connect 

one pair of wires to XMT+ and

XMT- (transmit positive and negative) on the terminal block, making
careful note of which color is positive and which color is negative.  

5. Connect the 

other pair of wires to RCV+ and RCV- (receive

positive and negative) on the terminal block, again making careful note
of which color is positive and which color is negative.

Ultimately, you will want to construct a two pair crossover cable that

makes a connection with the two Model 1004As as shown below.

6.  In a single pair circuit, use 

only the transmit (XMT) pair as

shown below:

7. If there is a shield around the telephone cable, it may be

connected to “G” on the terminal block.  To avoid ground loops, we
recommend connecting the shield at the computer end only.  A ground
wire is 

not necessary for proper operation of the Model 1004A.

9

10

XMT+--------------------------------------------------RCV+
XMT----------------------------------------------------RCV-
G ----------------------

G

RCV+--------------------------------------------------XMT+
RCV----------------------------------------------------XMT-

To Shield (Optional)

}

One Pair

}

One Pair

XMT+--------------------------------------------------XMT+
XMT----------------------------------------------------XMT-

Содержание 1004A

Страница 1: ...manufacture products for your unique needs We would like to hear from you Please contact us in any of the following ways to tell us how you like this product and how we can meet your product needs to...

Страница 2: ...rules which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installatio...

Страница 3: ...data rates 1 2 Kbps 19 AWG twisted pair The Model 1004A can handle up to 50 terminal drops in a multipoint polling environment For RS 485 and serial printer applications requiring hardware handshakin...

Страница 4: ...ction If you have additional questions contact Technical Support at 301 975 1000 Note Switches S1 1 S1 2 should be switched simultaneously Switches S1 7 S1 8 should also be switched simultaneously S1...

Страница 5: ...the impedance of the input receiver You may select either a low impedance of 120 Ohms or a high impedance of 16 kOhms By selecting the proper impedance for each drop there may be up to 50 receivers i...

Страница 6: ...you to connect one or two pairs of bare wires to the Model 1004A you will need to open the case to access the terminal blocks The following instructions will tell you how to open the case connect the...

Страница 7: ...ct our technical support We have strain relief assemblies to accommodate most cable diameters RCV G XMT RCV G XMT 10 Insert the strain relief assembly and wire into the slot in the bottom half of the...

Страница 8: ...nnection to ground is optional RJ 45 Cable 4 Wire SIGNAL PIN PIN SIGNAL GND 2 7 GND RCV 3 5 XMT XMT 4 6 RCV XMT 5 3 RCV RCV 6 4 XMT GND 7 2 GND RJ 11 Cable 2 Wire SIGNAL PIN PIN SIGNAL XMT 3 3 XMT XMT...

Страница 9: ...ver cable wiring instructions and straight through cables between the slaves 4 3 CONNECTION TO THE RS 232 INTERFACE Once you have properly configured the Model 1004A and connected the twisted pair wir...

Страница 10: ...0W power dissipation at 1 mS Power Draws operating power from RS 232 data and control signals no AC power or batteries required Temperature 0 to 50 C Humidity 5 to 95 non condensing Size 2 66 x 2 10 x...

Отзывы: