PATON
StandardMIG
MMA/TIG/MIG/MAG
-28 -
4) [u.AF] Arc Force trigger level = 12V (by default)
a) 9 ... 18V (increment 1V)
5) [BAH] current‐voltage curve slope = 1.4V/A (by default)
a) 0.2 ... 1.8V/A (increment 0.4V/A)
6) [Sh.A] short arc welding = OFF (by default)
a) On
b) OFF
7) [BSn] voltage reduction unit = OFF (by default)
a) On
b) OFF
8) [Po.P] current pulsing power = OFF (by default))
a) 0[OFF] ... 80% (increment 1%)
9) [Fr.P] current pulsing frequency = 5.0Hz (by default)
a) 0.2 ... 500Hz (dynamic increment 0.1Hz … 1Hz)
10) [dut] mark‐to‐space ratio (duty ratio) is the ratio of larger current cycle to pulse
spacing in percent = 50% (by default)
a) 20 ... 80% (increment 1%)
TIG welding mode
0) [-2-] main parameter CURRENT = 100A (by default)
a) 8 ... 160А (increment 1А) for StandardMIG -160
b) 10 ... 200А (increment 1А) for StandardMIG -200
c) 12 ... 250А (increment 1А) for StandardMIG -250
1) [t.uP] current fade‐in time = 1.0s (by default)
a) 0.1 ... 15.0s (increment 0.1s)
2) [Po.P] current pulsing power = OFF (by default)
a) 0[OFF] ... 80% (increment 1%)
3) [Fr.P] current pulsing frequency = 10.0Hz (by default)
a) 0.2 ... 500Hz (dynamic increment 0.1Hz … 1Hz)
4) [dut] mark‐to‐space ratio (duty ratio) is the ratio of larger current cycle to pulse
spacing in percent = 50% (by default)
a) 20 ... 80% (increment 1%)
MIG/MAG welding mode
On the left indicator of the source:
0) [-3-] main displayed parameter VOLTAGE = 19.0V (by default)
a) 12.0 ... 28.0V (increment 0.1V)
1) [t.dn] voltage fade‐out time = 0.1s (by default)
a) 0.1 ... 5.0s (increment 0.1s)
2) [Po.P] voltage pulsing power = OFF (by default)
Содержание StandardMIG-160
Страница 1: ......
Страница 2: ...PATON StandardMIG MMA TIG MIG MAG 2 ...
Страница 7: ... 7 PATON StandardMIG MMA TIG MIG MAG ...