30 | P a g e
PATON
®
PSI PRO 315 A 400 V DC MIG/MAG TIG/MMA
TRESHOLD
ARC FORCE
Threshold voltage for the reduced-voltage welding mode:
12 V (default value)
a)
9 … 18 V (positive or negative increment 1 V)
VOLT-AMPER
CHARAKT.
Volt-ampere characteristic slope:
1.4 V/A (default value)
a)
0.2 … 1.8 V/A (positive or negative increment 0.4 V/A)
SHORT ARC
MODE
Short arc welding mode:
OFF (default value)
a)
ON
b)
OFF
VOLT
REDUCTION
DEVICE
Reduction of voltage:
OFF (default value)
a)
ON
b)
OFF
POWER OF
PULSE
Current pulse amplitude:
OFF (default value]
a)
0 [OFF] … 80% (positive or negative increment 1 %)
FREQUENCY
OF PULSE
Current pulse frequency:
50 Hz (default value]
a)
0.2 … 500 Hz (positive or negative increment 0.2 Hz ... 1 Hz)
DUTY CYCLE
OF PULSE
Duty cycle (the ratio of the pulse length to the pulse repetition period):
50% (default value)
a)
20 … 80% (positive or negative increment 1%)
7.2. ARGON SHIELDED TUNGSTEN-ARC WELDING PROCESS (TIG)
0) [-2-]
Basic indicated parameter:
welding current 100 A (default value)
a)
15 ... 315 А (positive or negative increment 1 А) for PSI 315 PRO 400 V
BUTTON OF
TORCH
Function of the button on the welding torch:
[LFT] (default value)
a)
[LFT] - contact arc starting, function TIG-LIFT
b)
[2T] - contactless arc starting, function TIG-2T
c)
[4T] - contactless arc starting, function TIG-4T
TIME PRE-GAS
Period of voltage reduction:
1.0 s (default value)
a)
0,1 ... 25s (krok zmiany 0,1s)
TIME POST-
GAS
Period of post weld gas purging =
1.5 s., (default value),
a)
0,1 ... 25 s. (regulation 0.1 s.)
PRIMARY ARC
Initial current (pilot arc current):
15 A (default value)
a)
15 … 50 A (positive or negative increment 1 A) for PSI 315 PRO 400 V
TIME UP ARC
Period of current rise:
1.0 s (default value)
a)
0.1 … 5.0 s (positive or negative increment 0.1 s)
TIME DOWN
ARC
Period of current reduction:
2.0 s (default value)
a)
0.1 … 5.0 s (positive or negative increment 0.1 s)
POST CRATER
ARC
Crater welding current:
20 A (default value)
a)
15 ... 50 А (
positive or negative increment
1 А)
for
PSI 315 PRO 400 V
POWER OF
PULSE
Current pulse amplitude:
OFF (default value]
a)
0 [OFF] … 80% (positive or negative increment 1%)
FREQUENCY
OF PULSE
Current pulse frequency: 10
.0 Hz (default value]
a)
0.2 … 500 Hz (positive or negative increment 0.1 Hz)
DUTY CYCLE
OF PULSE
Duty cycle (the ratio of the pulse length to the pulse repetition period):
50% (default value)