
29 | P a g e
PATON
®
PSI PRO 315 A 400 V DC MIG/MAG TIG/MMA
6.1. SWITCHING TO THE REQUIRED FUNCTION
To enter the advanced settings of the device function, keep the button
(3)
pressed for more than
5 seconds. After pressing the button
(3)
, the graphical name of the current function will be shown on
the display. After releasing the button, the display will show the standard value of this function, which
can be increased or decreased using the buttons
(1).
In the situation of fast pressing and releasing the
button
(3)
, you can switch over to the next functions of the welder in the circle, the same situation
applies to the button
(10)
on the wire feeder, the adjustment takes place via the buttons
(8).
ATTENTION!
If button
(3)
is held for more than 12 s, the display will show
readouts 333 … 222 … 111 … 000. In this state, release the button before the
end of the readout indication period (000); otherwise, all the values of the
functions and parameters of the welding unit will return to the default factory
values set for the current welding process
(see Section 6.3)
6.2 CHOOSING A LANGUAGE ON THE DEVICE
The following languages are installed in the device: English, Russian.
1.
When the device is turned off, press and hold the "MENU" button, then start the device with the main
switch.
2.
The language change function appears on the main screen. To change the language, press the "+" or "-"
button.
3.
After selecting the appropriate language, wait 2 seconds. , the selected language will be automatically
saved.
4.
Repeat points 1 to 3 to change the language again.
6.3. SWITCHING TO THE REQUIRED WELDING PROCESS
After pressing the button
(4)
, the device switches to the next welding method. The methods switch
over and over, you can see it on the icons
(4)
on the front panel, which will be highlighted.
6.4. RESETTING ALL FUNCTIONS CURRENT WELDING METHOD
There might be conditions when the operator cannot set the welding unit parameters properly. In this
case, press button
(3)
and hold it for more than 12 s. At the 5th second, the welding unit will be ready
to switch to the next welding process. Nevertheless, hold the button. After 5 seconds, the display will
show readouts 333 … 222 … 111 … 000. When the readout is 000, the values of the functions and
parameters of the welding unit will return to the default factory set values. These operations for setting
default parameter values should be performed individually for all the welding processes of the welding
unit.
7. GENERAL LIST OF FUNCTION SEQUENCES
7.1. MANUAL ARC WELDING PROCESS (MMA)
0) [-1-]
Basic indicated parameter: welding current
15 А (default)
a)
15 … 315 A (positive or negative increment 1 А) for PSI 315 РRO 400 V
POWER HOT
START
Current intensity in the increased-current arc starting mode:
40% (default value)
a)
0 [OFF] … 100% at low currents (positive or negative increment 1 %)
TIME HOT
START
Period of the increased-current arc starting:
0.3 s (default value)
a)
0.1 … 1.0 s (positive or negative increment 0.1 s)
POWER ARC
FORCE
Voltage in the reduced-voltage welding mode:
40% (default value)
a)
0 [OFF] … 100% at low currents (positive or negative increment 1%)