27 | P a g e
PATON
®
PSI STANDARD SERIES DC MIG/MAG TIG/MMA
3) FREQUENCY OF
PULSE
Current pulse frequency:
5.0 Hz (default value]
a)
0.2 … 50 Hz (adjustment 1 Hz)
4) DUTY CYCLE OF
PULSE
Duty cycle (the ratio of the pulse length to the pulse repetition period):
50% (default value)
a)
20 … 80 % (adjustment 1%)
7.3. SEMIAUTOMATIC ARC WELDING PROCESS (MIG/MAG)
0) [-3-]
Basic indicated parameter: welding voltage
19.0 V (default value)
a)
12 … 24 V (adjustment 0.1 V) for PSI 160 STANDARD
b)
12 … 26 V (adjustment 0.1 V) for PSI 200 STANDARD
c)
12 … 28 V (adjustment 0.1 V) for PSI 250 STANDARD 230V
d)
12 … 28 V (adjustment 0.1 V) for PSI 250 STANDARD 400V
1) BUTTON OF
TORCH
Mode on the torch button
[2T] (default value)
a)
2T
b)
4T
c) _
4T
2). INDUCTANCE
Select one of three function levels: =
OFF (default value)
(a)
1
st
stage – Hardest arc
(b)
2
nd
stage – Average arc
3
rd
stage – Softest arc
3). TIME PRE GAS
Period of pre gas outflow before welding (1.0s by default)
a)
0,1 ... 25s (krok zmiany 0,1s)
4) TIME POST GAS
Period of post weld gas purging =
1.5 s., (default value),
a)
0,1 ... 25 s. (regulation 0.1 s.)
5) TIME UP
VOLTAGE
Period of voltage increase: 1.0 s (default value)
a)
0.1 … 5.0 s (positive or negative increment 0.1 s)
6) TIME DOWN
VOLTAGE
Period of voltage reduction:
1.0 s (default value)
a)
0.1 … 5.0 s (adjustment 0.1 s)
7) POWER OF PULSE
Voltage pulse amplitude:
OFF (default value)
a)
0 [OFF] … 80% (adjustment 1 %)
8) FREQUENCY OF
PULSE
Voltage pulse frequency:
20 Hz (default value)
a)
5 … 200 Hz (adjustment 1 Hz)
9) DUTY CYCLE OF
PULSE
Duty cycle (the ratio of the pulse length to the pulse repetition
period):
50 % (default value)
a)
20 … 80% (adjustment 1 %)
7.3.1 WIRE FEEDER FUNCTION WELDING PROCESS (MIG/MAG)
0) WIRE SPEED
Basic indicated parameter
SPEED = 7,0 m/min (default value)
a)
2,0 ... 16 m/min (adjustment 0,1 m/min)
1) BUTTON OF
TORCH
Mode on the torch button
[2T] (default value)
a)
2T
b)
4T
c) _
4T
2) TIME PRE GAS
Period of preweld gas purging =
0.5 s., (default value),
a)
0,1 ... 25 s. (adjustment 0.1 s.)
3) TIME POST GAS
Period of post weld gas purging =
1.5 s., (default value),
a)
0,1 ... 25 s. (adjustment 0.1 s.)
Содержание PSI 160 Standard