Paton PSI 160 Standard Скачать руководство пользователя страница 19

18 | P a g e  

PATON

®

 

PSI STANDARD SERIES DC MIG/MAG TIG/MMA 

4.4. LINEAR INCREASE OF WELDING CURRENT  

This function provides the economic consumption of an electrode, promotes the extension of the service 
life of the welding torch, and facilitates the use of the welding torch. This function prevents the spillage 
of molten metal in the welding pool. Additionally, during the period 

[TIME UP ARC]

 of linear increase of 

the welding current, it is possible to accurately locate the welding torch in the weld area, as the arc 
starting point is initially not always is located in the weld area. It is reasonable to heat the weld area. By 
default, the period of linear increase of welding current is 

1.0 s

 

The procedure for changing the values of the operational parameters of the welding unit is described in Section 

6.1. 

 
4.5. WELDING AT PULSE WELDING CURRENT  

This function is designed to simplify the control of a welding process in various spatial welding positions, 
excluding  a  flat  welding  position.  This  function  is  also  used  in  welding  nonferrous  metals.  When  this 
function is activated, the application of pulse welding current improves the mixing of molten metals in the 
weld area and causes forced action on the transfer of molten metal drops into the welding pool, therefore 
the  stability  of  the  weld  formation  and  the  stability  of  the  welding  process  are  improved.  The  pulse 
welding current in the manual arc welding process affects the weld parameters similar to the movement of 
the operator hand in manual arc welding process, specifically at hard-to-reach places.  

 

The proper adjustment  of the welding process parameters in  the welding at  pulse welding current  has a 
direct effect on the weld quality, specifically reduces weld metal porosity and decreases the graininess of 
the weld metal. As a result of the improved weld quality, the weld strength increases. 
 

To  activate  this  function,  it  is  necessary  to  set  the  following  three  operational  parameters  of  the 

welding process: current pulse amplitude 

[POWER OF PULSE]

, current pulse frequency 

[FREQUENCY OF 

PULSE]

,  and  duty  cycle 

[DUTY  CYCLE  OF  PULSE]

.  By  default,  the  current  pulse  amplitude  is  0 

[OFF], 

that is, the function is switched off, the current pulse frequency is 5 Hz, and the duty cycle is 50 %. To 
activate the function, set the current pulse amplitude 

[POWER OF PULSE]

 higher than 0. The current pulse 

amplitude should be set in percentage of the welding current specified for the welding process. 
 

Example

Welding  is  to  be  performed  with  welding  no  consumable  tungsten  electrode  2.0  mm  in 
diameter.  The  set  welding  current  is  100  A.  The  current  pulse  amplitude  is  30  %.  The 
current pulse frequency is 5 Hz (default value). The duty cycle is 50 % (default value). 

 

The result is 

the following: the welding current pulse amplitude will be in the range of 70 … 130 A, the 

current pulse frequency will be 5 Hz, and the current pulse length will be equal to the length 
of an interval between pulses. If the duty cycle is not equal to 50 %, the current pulses will 
be nonsymmetrical relative to the intervals between pulses, but the average welding current 
value will be equal to the set welding current value of 100 A. As a result, the average heat 
input to the weld will not change. 

 

Default value 

"duty cycle" 

 = 50%

 

"duty cycle" 

 = 20% 

"duty cycle" 

 = 70% 

 

 
 

 

t, s 

t, s 

t, s 

Содержание PSI 160 Standard

Страница 1: ......

Страница 2: ...G UNIT 14 3 7 SHORT ARC WELDING MODE 14 3 8 REDUCTION OF OPEN CIRCUIT VOLTAGE 15 3 9 WELDING AT PULSE WELDING CURRENT 15 4 ARGON ARC WELDING PROCESS TIG 16 4 1 PREPARING THE WELDING UNIT FOR OPERATION...

Страница 3: ...MMA 26 7 2 ARGON SHIELDED TUNGSTEN ARC WELDING PROCESS TIG 26 7 3 SEMIAUTOMATIC ARC WELDING PROCESS MIG MAG 27 7 3 1 WIRE FEEDER FUNCTION WELDING PROCESS MIG MAG 27 8 MAINTENANCE 28 9 OPERATION WITH A...

Страница 4: ...sure that all product in series production are in conformity with the product sample detailed in this report The applicant should hold the whole technical report at disposal of the competent all the r...

Страница 5: ...t more than 80 Not more than 0 6 mm 1 0 75 1 5 115 2 0 160 2 5 195 4 0 310 3 mm Not more than 120 Not more than 0 8 mm 1 5 75 2 0 105 2 5 130 4 0 205 6 0 310 4 mm Up to 160 Not more than 1 0 mm 2 0 75...

Страница 6: ...operating modes of the unit This welding unit is designed for household and semi industrial use It provides a good load duration at full rated current of 200A and 250A respectively when powered by a p...

Страница 7: ...e automatically varied depending on the temperature inside the unit This feature allows the service life of the ventilator to be increased and additionally dust content inside the unit to be reduced 6...

Страница 8: ...n against electrode sticking Automatic Automatic Automatic Reduction of open circuit voltage ON OFF ON OFF ON OFF Open circuit voltage in the manual arc welding process V 12 75 12 75 12 75 Welding arc...

Страница 9: ...OF THE WELDING CABLES ARE INDICATED BELOW Cable length m Maximum current A Cross section area of the cable conductor mm2 Cable designation 4 12 m Not more than160 16 mm2 KG 1 16 5 15 m Not more than...

Страница 10: ...utton is pressed gas feed is switched off 7 Button for adjusting the wire feed speed and parameters of the feeder function 8 Digital display showing the wire feed speed and feeder functions 9 The butt...

Страница 11: ...s shielded arc welding GMAW or flux cored arc welding FCAW or FCA for a semi automatic or automatic arc welding process Any other use of the welding unit is considered as improper The manufacturer of...

Страница 12: ...s connected to a power supply voltage of over 270 V and three phase to 460 V This situation can occur if the phase voltages in the standard power system are unbalanced or if you use a non standard con...

Страница 13: ...tch 14 the welding electrode is under voltage Do not allow the electrode to contact current conducting or grounded parts such as the casing of the welding unit because such a contact will cause the st...

Страница 14: ...Improved arc starting 4 Reduced probability of electrode sticking see Section 3 5 Manual adjustment operations allow the minimum welding voltage to be set in order to slightly decrease power consumpt...

Страница 15: ...AKTERISTIC of the welding unit is 1 4 V A This value is optimal for the most common electrodes and with rutile coating In order to facilitate welding with electrodes with standard coating it is recomm...

Страница 16: ...or hand in manual arc welding process specifically at hard to reach places The proper adjustment of the welding process parameters in the welding at pulse welding current has a direct effect on the we...

Страница 17: ...combustive gases The use of other gases is allowed only by agreement with the manufacturer of the welding unit Preparation the welding unit for TIG LIFT operation 1 Connect the TIG torch into socket...

Страница 18: ...on of the control button on the welding torch is set by default and is designed for welding torches with contact arc starting without using oscillators and other like devices In contrast to convention...

Страница 19: ...ly at hard to reach places The proper adjustment of the welding process parameters in the welding at pulse welding current has a direct effect on the weld quality specifically reduces weld metal poros...

Страница 20: ...welding process are described in Section 6 1 5 SEMIAUTOMATIC ARC WELDING PROCESS MIG MAG ATTENTION As the shielding gas during welding of carbon steel carbon dioxide CO2 is used it is the cheapest opt...

Страница 21: ...should be minimum necessarily tightened and should easily spin but it should not turn 13 Switch the button 4 to the MIG MAG welding position if the desired welding method has been skipped press the b...

Страница 22: ...MA 5 2 OPERATIONAL CYCLE OF THE WELDING PROCESS MIG MAG 5 2 1 OPERATIONAL CYCLE OF THE WELDING PROCESS MIG MAG 2T The procedure for changing the values of the operational parameters of the welding uni...

Страница 23: ...h the shielding gas TIME POST GAS the gas valve is closed with a delay In the alternative mode of the _4T button we omit the first release of the button and this is different from the standard 4T mode...

Страница 24: ...lated reduction period TIME DOWN VOLTAGE is 1 0 s and can be varied by the operator at his option see Section 6 1 5 6 FUNCTION OF POSTWELD GAS CLEANING This function is intended to clean the shielding...

Страница 25: ...duty cycle DUTY CYCLE OF PULSE is 50 To activate the function set the voltage pulse amplitude POWER OF PULSE higher than 0 The voltage pulse amplitude should be set in percentage of the welding voltag...

Страница 26: ...nter the advanced settings of the device function keep the button 3 pressed for more than 5 seconds After pressing the button 3 the graphical name of the current function will be shown on the display...

Страница 27: ...lue a 9 18 V adjustment 1 V 5 VOLT AMPER CHARAKT Volt ampere characteristic slope 1 4 V A default value a 0 2 1 8 V A adjustment 0 4 V A 6 SHORT ARC MODE Short arc welding mode OFF default value a ON...

Страница 28: ...y default a 0 1 25s krok zmiany 0 1s 4 TIME POST GAS Period of post weld gas purging 1 5 s default value a 0 1 25 s regulation 0 1 s 5 TIME UP VOLTAGE Period of voltage increase 1 0 s default value a...

Страница 29: ...ime intervals check that the safety requirements in operation of the welding unit are fulfilled see Section 15 Safety instructions 2 At half yearly intervals purge the welding unit with dry compressed...

Страница 30: ...ltage the specification data of the unit are indicated on the nameplate on the rear panel of the unit In this case the electrical outlet of the power supply system and the power cable of the welding u...

Страница 31: ...ired equipment The basic warranty obligations do not include devices 1 Mechanical damage affected the availability of the device deformation body parts and in consequence of a fall or drop heavy objec...

Страница 32: ...MENT applies to households Do not dispose of electrical equipment together with normal waste In observance of European Directive 2012 19 EC on Waste Electrical and Electronic Equipment WEEE and its im...

Страница 33: ...electric shock so avoid touching them with bare hands and wet or damaged protective clothing Protective clothing should not restrain movements If possible it should not be made of synthetic materials...

Страница 34: ...lop during the burn can cause skin burns Wear protective gloves and pliers when touching or moving the welded item ELECTRIC POWER SOURCES It is forbidden to work with damaged welding wires or on wet s...

Страница 35: ...r welding work in an environment of higher standard of electric shock It is recommended that the power line be provided with a separate protection against the shock absorber 17 ELECTRICAL SCHEMATIC DI...

Страница 36: ..._________ signature of the seller PATON SERVICE CENTER Kapita owa 4 Street Rzesz w City Poland zip code 35213 Head of Service Center Piotr B aszkowski Phone 48 22 290 86 96 e mail service patonwelder...

Страница 37: ...AND FAULTY CONDITION CAUSE Tel Technical support 48 22 290 86 96 Address of the service center 35213 Poland Rzesz w 4 Kapita owa Street DATE OF REPORT TO REPAIR DATE OF SERVICE REPAIR _______________...

Страница 38: ...TY CONDITION CAUSE Tel Technical support 48 22 290 86 96 Address of the service center 35213 Poland Rzesz w 4 Kapita owa Street DATE OF REPORT TO REPAIR DATE OF SERVICE REPAIR ________________ _______...

Отзывы: