– 10 –
TYPE
NE-M1A
(1) (5)
(2)
(3)
(4)
Installation Example
Positioning Mark
< Locked >
< Unlocked >
(1) Remove the globe by unscrewing it in a counter-clockwise
direction.
(2) Punch-out the mounting holes on the case and buzzer
case by drilling holes from the top.
(3) Peel off the adhesive paper from the waterproof sheet
and apply it to the case.
(4) Af
fi
x the product to the installation surface with screws
and nuts.
(Installation screws and nuts are not included with this
product.)
(5) Set the globe with aligning the positioning mark after
attaching the case, then turn the globe clockwise to lock
it.
Installation Dimension [Unit: mm]
35.5
Wire Exit Hole
Installation Holes
(Ø 16) When the Cable Gland is used: Ø 26
(2 - Ø 4.5)
M4 screw (Tightening torque: 0.6 N•m)