manualshive.com logo in svg
background image

PS-3220

 Introduction

3

013-16026A

Initial Step: Charge the Battery

Connect the Cable

: On the back of the 

Wireless Drop Counter, pry open the rubber 
seal that covers the Micro USB port. Use the 
included Micro USB Cable to connect the 
micro USB port on the back of the sensor to a 
USB 

port

 or USB 

charger

 such as the 

PASCO PS-2575 USB Single Port Charger. 
Charging begins automatically. The charger 
circuit inside the sensor turns itself off when 
the unit is fully charged. The battery status LED will shine yellow as the battery is charging, and will shine green 
when the battery is charged. The battery is partially charged at the factory. Initial charging time may be three 
hours or longer depending on the power source and the condition of the battery. 

Using the Sensor

The sensor is designed to work with PASCO data collection software to measure the number of drops that fall 
through the drop window. 

ON/OFF and Sleep Information

Before turning the sensor on, make sure that nothing is blocking the drop window. To turn the sensor on, press and 

hold

 the ON button. When the battery status LED shines red for a moment, release the ON button. Then, the 

Bluetooth status LED will blink. This indicates that the sensor is ready to be “paired” with a device using the data 
collection software. NOTE: The sensor calibrates itself each time that it is turned on and therefore it is important 
that the drop window is unblocked when the sensor is turned on.

To turn the sensor off, press and 

hold

 the ON button for a moment until the battery status LED shines red. Release 

the ON button and the Bluetooth status LED stops blinking. The sensor puts itself to sleep after one hour of 
inactivity if connected, and after several minutes if not connected. 

Data Collection Software

See the PASCO web site at 

www.pasco.com/software

 for help in selecting the right PASCO software and to 

check for the latest versions.

Software Help

In Sparkvue, open the Main Menu and select “Help” for information about collecting, displaying, and analyzing 
data. 

PASCO Capstone

SPARKvue

Mac OS X

Mac OS X

Windows

Windows

iOS 

Android

Chromebook

Device 

ID

Pry open the cover.

Micro USB Port

USB Port Cover 

open position

Содержание PS-3214

Страница 1: ...Reference Guide 013 16026A Wireless Drop Counter PS 3214 a b d c e f Power Rechargeable Battery or USB Cable Connection...

Страница 2: ...t or smart phone when the sensor is connected PASCO Capstone will work on a PC or Mac The Wireless Drop Counter can be mounted on a support rod The counter is equipped with two integrated probe holder...

Страница 3: ...blocking the drop window To turn the sensor on press and hold the ON button When the battery status LED shines red for a moment release the ON button Then the Bluetooth status LED will blink This ind...

Страница 4: ...elp from the Help menu or press F1 LED Information The drop LED operates as follows The drop LED blinks when a drop is detected passing through the drop window If the lens in the drop window becomes o...

Страница 5: ...in the liquid in the beaker Assemble the Drop Dispenser 1 Remove the plunger from the syringe Remove the protective white plastic caps from the stopcock valves 2 Connect the two stopcocks together Con...

Страница 6: ...e figure on next 6 013 16026A Syringe with 50 mL of 0 1 M NaOH Wireless pH Sensor Direct Connect pH Probe Wireless Drop Counter Drop Tip Stopcock Stopcock Syringe Holder Support Rod Micro Stir Bar Mag...

Страница 7: ...drops from the drop tip and give you a measure of the volume 5 Start Capstone Pair the Wireless Drop Counter wirelessly to the computing device e g computer In Capstone open the Hardware Setup window...

Страница 8: ...om stopcock so that the drops fall at a rate of about 1 drop per second Close the top valve after the rate is achieved Discard the titrant as directed by your instructor 4 Align the drop tip with the...

Страница 9: ...me is the measurement selected as default The Templates window also opens with Graph Table and Graph and Digits as the choices 8 In the Templates window touch or click the Graph template to open a Gra...

Страница 10: ...e that the Fluid Volume measurement also has a Calibrate measurement icon 10 Click or touch the Calibrate measurement icon to open the Calibrate Sensor Select Measurement window 11 In the Calibrate Se...

Страница 11: ...the number of drops as they are counted 13 After about 5 mL of titrant has collected in the graduated cylinder close the bottom stopcock Carefully measure the exact volume of titrant in the graduated...

Страница 12: ...ibrate Acid Base Titration Calibration Method 1 Setup the equipment and consumables as shown 2 Start the data acquisition software 3 In the software pair connect the Wireless Drop Counter and a Wirele...

Страница 13: ...d then back on Retry If the Wireless Drop Counter will not turn on use the micro USB cable to connect it to a USB port or charger See the PASCO web site at www pasco com for more information Probe Car...

Страница 14: ...e that it will be recycled in a manner that protects human health and the environment To find out where you can drop off your waste equipment for recycling please contact your local waste recycle disp...

Страница 15: ...he System Report button Select Bluetooth from the sidebar on the left underneath Hardware Scan down the list of information until you find LMP Version If your Mac is equipped with Bluetooth SMART the...

Страница 16: ...Wireless Drop Counter Appendix A Bluetooth Compatibility 16 013 16026A...

Отзывы: