background image

3

 

Control Board 

This section identifies the main control board connections. 

code 

function 

socket

 

color

 

plug 
color 

wire color  wire label  remark 

SWS 

water level switch 

white 

white 

white x2 

SWS 

ZFS 

evaporator temperature 
sensor 

red 

red 

white+black  ZFS 

LNS 

condenser temperature 
sensor 

purple 

purple  white+red 

LNS 

HP 

refrigerant pressure sensor 

black 

not in use 

SEN1 

ice cube flap switch 

red 

red 

white x2 

SEN1 

CZ1 

front control panel 

white 

white 

white x6 

CZ1 

CZ3 

secondary coil transformer 

white 

white 

blue x2 

CZ3 

CZ5 

primary coil transformer 

white 

white 

red x2 

CZ5 

N1 

neutral of reversing valve 

1/

4” male 

white 

blue 

N1 

N2 

neutral of pump & discharge 
valve 

1/4” male 

white 

white x2 

N2 

N3 

neutral of compressor 

1/4” male 

white 

white 

N3 

COM 

line (general power) 

1/4” male on relay  brown  black 

COM 

NO 

line of compressor 

1/4” male on relay  brown  orange 

NO 

PSF1 

line of discharge valve 

1/4” male 

white 

blue 

PSF1 

FJ1 

line of fan motor 

1/4” male 

white 

brown 

FJ1 

SF1 

line of inlet valve 

1/4” male 

white 

grey 

SF1 

SB1 

line of pump 

1/4” male 

white 

red 

SB1 

RF1 

line of reversing valve 

1/4” male 

white 

blue 

RF1 

FUSE1  fuse for transformer 

1A 250V 

marked on board 

FUSE2  fuse (general exclude 

compressor) 

6.3A 250V  marked on board 

The main control board is located on the back of the ice machine, within the metal box. 
This list is made available for reference to help a serviceman in the replacement of a main 
control board. 

Содержание IM70

Страница 1: ...be used by qualified technicians only Parts Connect does not assume any responsibility for property damage or personal injury for improper service procedures by an unqualified person Model IM70 Made i...

Страница 2: ...2 This page intentionally left blank...

Страница 3: ...4 male white blue N1 N2 neutral of pump discharge valve 1 4 male white white x2 N2 N3 neutral of compressor 1 4 male white white N3 COM line general power 1 4 male on relay brown black COM NO line of...

Страница 4: ...umber is larger than 180 days the filter light will stay on Advice to the homeowner is to change the filter After home owner changes the filter a medium press of the reset button resets the days to ze...

Страница 5: ...to a fixed number ice making light on the fixed number in SMG is the ice making time during last ice making cycle This operation is to help serviceman find problems of last ice making 6 all except SM...

Страница 6: ...xx Parameter 5 used to set the gap between 2 self clean procedures Short press set button can change the 5xx from 500 to 590 see self clean frequency table long press mode button release and then shor...

Страница 7: ...s mode button 10 time SMG show OFF for 10 seconds and then show 2xx 3xx 4xx 5xx 6xx 7xx 8xx 9xx Pxx Axx CLx Parameter CL is used to turn on off the startup clean feature CL0 is no startup clean CL1 me...

Страница 8: ...he maximum ice making time the system will give an error code The reason normally is because the evaporator not cold enough Maximum Harvest Time parameter refer to 300 0 min 301 1 min 302 2 min 303 3...

Страница 9: ...y 30 ice making cycles 540 every 40 ice making cycles 550 every 50 ice making cycles 560 every 60 ice making cycles 570 every 70 ice making cycles 580 every 80 ice making cycles 590 every 90 ice makin...

Страница 10: ...n 803 3 min The maximum water filling time is used to prevent the inlet water valve from burning out if water filling time is too long Which is normally caused by water supply pressure too low Ice Mak...

Страница 11: ...nser fan It is suggested to not change the default unless the circumstance temperature is extremely low or high Water Discharge Frequency parameter refer to P00 no discharge P01 every 1 ice making cyc...

Страница 12: ...clean CL1 have startup clean Startup clean is only available during system power on and started The water discharge process is used for situations where the water tank is too cold Possibly some of the...