background image

4

 

Button Operation

The status and time lapse are dependent when pressing buttons. 

status 

main power off 

ice machine power is unplugged or main power switch is turned off 

SMG off 

ice machine is plugged in and main power switch is on but SMG shows OFF 

setting 

ice machine is in setting mode. While SMG shows OFF long press "mode" button 
enters setting mode. 

ice making cycle 

include following status: ice making, harvest, pre-chill 

press 

short 

press the button more than 1 second, less than 3 seconds and then release 

medium 

press the button more than 3 seconds, less than 10 seconds and then release 

long 

press the button more than 10 seconds and then release 

status 

operation 

lights and SMG 

shown 

details 

main power 
off 

turn on the main power 
switch at front lower right 
side of ice machine 

power light

on 

SMG

OFF 

main switch controls the general 
power of the ice machine. Suggest 
to turn it off if ice machine is not for 
use for a long time. 

SMG: OFF 

long press "set" button 

SMG:  shows number 
between 001 to 180      
filter light: flash 

the number shows the days the 
filter has been in use. When the 
number is larger than 180 days the 
filter light will stay on. Advice to the 
homeowner is to change the filter. 
After home owner changes the 
filter a medium press of the reset 
button resets the days to zero. 

short press "reset" button, 
before release, short press 
"on/off" button 

SMG: shows 888 for 1 
second then shows 
PPP for 3 seconds    
all other lights: on for 1 
second and then off 

this operation is to reset all 
settings to "default factory" 
settings. 

short press "on/off" button 

SMG: shows 888 for 1 
second then shows 
COO    
all other lights: on for 1 
second and then off 

this operation turns on the ice 
machine and starts the ice making 
process. 

setting 

long press "reset" button 

SMG: shows XXX for 
10 seconds and then 
shows UUU for 3 
seconds 
all other lights: on for 1 
second and then off 

XXX means the last number shows 
in SMG during setting, after 
setting, do this operation, can 
upload the last setting to ice 
machine as default. (don't show 
house owner this operation, this 
will cause problems if they change 
the default. This is only for 
serviceman if the ice machine use 
for extremely hot or cold place, 
change default can help house 
owner minimum the problems.) 

ice making 

medium press "clean" button  SMG: shows current 

number for 3 seconds 

the fixed number in SMG is the 
harvest time during last ice making 

Содержание IM70

Страница 1: ...be used by qualified technicians only Parts Connect does not assume any responsibility for property damage or personal injury for improper service procedures by an unqualified person Model IM70 Made i...

Страница 2: ...2 This page intentionally left blank...

Страница 3: ...4 male white blue N1 N2 neutral of pump discharge valve 1 4 male white white x2 N2 N3 neutral of compressor 1 4 male white white N3 COM line general power 1 4 male on relay brown black COM NO line of...

Страница 4: ...umber is larger than 180 days the filter light will stay on Advice to the homeowner is to change the filter After home owner changes the filter a medium press of the reset button resets the days to ze...

Страница 5: ...to a fixed number ice making light on the fixed number in SMG is the ice making time during last ice making cycle This operation is to help serviceman find problems of last ice making 6 all except SM...

Страница 6: ...xx Parameter 5 used to set the gap between 2 self clean procedures Short press set button can change the 5xx from 500 to 590 see self clean frequency table long press mode button release and then shor...

Страница 7: ...s mode button 10 time SMG show OFF for 10 seconds and then show 2xx 3xx 4xx 5xx 6xx 7xx 8xx 9xx Pxx Axx CLx Parameter CL is used to turn on off the startup clean feature CL0 is no startup clean CL1 me...

Страница 8: ...he maximum ice making time the system will give an error code The reason normally is because the evaporator not cold enough Maximum Harvest Time parameter refer to 300 0 min 301 1 min 302 2 min 303 3...

Страница 9: ...y 30 ice making cycles 540 every 40 ice making cycles 550 every 50 ice making cycles 560 every 60 ice making cycles 570 every 70 ice making cycles 580 every 80 ice making cycles 590 every 90 ice makin...

Страница 10: ...n 803 3 min The maximum water filling time is used to prevent the inlet water valve from burning out if water filling time is too long Which is normally caused by water supply pressure too low Ice Mak...

Страница 11: ...nser fan It is suggested to not change the default unless the circumstance temperature is extremely low or high Water Discharge Frequency parameter refer to P00 no discharge P01 every 1 ice making cyc...

Страница 12: ...clean CL1 have startup clean Startup clean is only available during system power on and started The water discharge process is used for situations where the water tank is too cold Possibly some of the...