6

 

Parameter Setting 

status 

operation 

lights and SMG shown 

details 

ice making 
cycle 

short press mode button 

SMG: show current 
number for 2 seconds 
and then show 1xx 
ice making light: on 

Parameter 1 is used to modify the 
thickness of ice cubes. xx will flash 
during setting. Short press set button 
can change the 1xx, from 100 to 119, 
100 is thinnest. after setting, leave it 
no-operation for 10 seconds and 
system will automatically remember 
the setting and go back to ice making 
cycle. Default number is 111. 

SMG: OFF  long press mode button 

SMG: show OFF for 10 
seconds and then show 
2xx 

Parameter 2 used to set the ice 
making time. Short press the set 
button will change the 2xx from 200 to 
209, see ice making time table. 

long press mode button, 
release and then short 
press mode button 1 time 

SMG: show OFF for 10 
seconds and then show 
2xx->3xx 

Parameter 3 used to set the harvest 
time. Short press the set button will 
change the 3xx from 300 to 309, see 
harvest time table. 

long press mode button, 
release and then short 
press mode button 2 time 

SMG: show OFF for 10 
seconds and then show 
2xx->3xx->4xx 

Parameter 4 used to set the pre-chill 
time. Short press the set button will 
change the 4xx from 400 to 490, see 
pre-chill time table. 

long press mode button, 
release and then short 
press mode button 3 time 

SMG: show OFF for 10 
seconds and then show 
2xx->3xx->4xx->5xx 

Parameter 5 used to set the gap 
between 2 self-clean procedures. 
Short press set button can change the 
5xx from 500 to 590, see self-clean 
frequency table. 

long press mode button, 
release and then short 
press mode button 4 time 

SMG: show OFF for 10 
seconds and then show 
2xx->3xx->4xx->5xx->6xx 

Parameter 6 used to set the maximum 
lack-of-water alarm time. Short press 
set button can change the 6xx from 
600 to 609, see maximum lack-of-
water table. 

long press mode button, 
release and then short 
press mode button 5 time 

SMG: show OFF for 10 
seconds and then show 
2xx->3xx->4xx->5xx-
>6xx->7xx

Parameter 7 is used to set the 
maximum water inlet time. Short press 
set button can change the 7xx from 
700 to 709, see maximum water inlet 
table. 

long press mode button, 
release and then short 
press mode button 6 time 

SMG: show OFF for 10 
seconds and then show 
2xx->3xx->4xx->5xx-
>6xx->7xx->8xx

Parameter 8 is used to set the ice 
making lapse time. Short press set 
button can change the 8xx from 800 to 
809, see ice making lapse table. 

long press mode button, 
release and then short 
press mode button 7 time 

SMG: show OFF for 10 
seconds and then show 
2xx->3xx->4xx->5xx-
>6xx->7xx->8xx->9xx

Parameter 9 is used to set the 
maximum condenser temperature. 
Short press set button can change the 
9xx from 900 to 909, see maximum 
condenser temperature table. 

long press mode button, 
release and then short 
press mode button 8 time 

SMG: show OFF for 10 
seconds and then show 
2xx->3xx->4xx->5xx-

Parameter P is used to set the water 
discharge frequency. Short press set 
button can change the Pxx from P00 to 

Содержание IM70

Страница 1: ...be used by qualified technicians only Parts Connect does not assume any responsibility for property damage or personal injury for improper service procedures by an unqualified person Model IM70 Made i...

Страница 2: ...2 This page intentionally left blank...

Страница 3: ...4 male white blue N1 N2 neutral of pump discharge valve 1 4 male white white x2 N2 N3 neutral of compressor 1 4 male white white N3 COM line general power 1 4 male on relay brown black COM NO line of...

Страница 4: ...umber is larger than 180 days the filter light will stay on Advice to the homeowner is to change the filter After home owner changes the filter a medium press of the reset button resets the days to ze...

Страница 5: ...to a fixed number ice making light on the fixed number in SMG is the ice making time during last ice making cycle This operation is to help serviceman find problems of last ice making 6 all except SM...

Страница 6: ...xx Parameter 5 used to set the gap between 2 self clean procedures Short press set button can change the 5xx from 500 to 590 see self clean frequency table long press mode button release and then shor...

Страница 7: ...s mode button 10 time SMG show OFF for 10 seconds and then show 2xx 3xx 4xx 5xx 6xx 7xx 8xx 9xx Pxx Axx CLx Parameter CL is used to turn on off the startup clean feature CL0 is no startup clean CL1 me...

Страница 8: ...he maximum ice making time the system will give an error code The reason normally is because the evaporator not cold enough Maximum Harvest Time parameter refer to 300 0 min 301 1 min 302 2 min 303 3...

Страница 9: ...y 30 ice making cycles 540 every 40 ice making cycles 550 every 50 ice making cycles 560 every 60 ice making cycles 570 every 70 ice making cycles 580 every 80 ice making cycles 590 every 90 ice makin...

Страница 10: ...n 803 3 min The maximum water filling time is used to prevent the inlet water valve from burning out if water filling time is too long Which is normally caused by water supply pressure too low Ice Mak...

Страница 11: ...nser fan It is suggested to not change the default unless the circumstance temperature is extremely low or high Water Discharge Frequency parameter refer to P00 no discharge P01 every 1 ice making cyc...

Страница 12: ...clean CL1 have startup clean Startup clean is only available during system power on and started The water discharge process is used for situations where the water tank is too cold Possibly some of the...

Отзывы: