6
Parameter Setting
status
operation
lights and SMG shown
details
1
ice making
cycle
short press mode button
SMG: show current
number for 2 seconds
and then show 1xx
ice making light: on
Parameter 1 is used to modify the
thickness of ice cubes. xx will flash
during setting. Short press set button
can change the 1xx, from 100 to 119,
100 is thinnest. after setting, leave it
no-operation for 10 seconds and
system will automatically remember
the setting and go back to ice making
cycle. Default number is 111.
2
SMG: OFF long press mode button
SMG: show OFF for 10
seconds and then show
2xx
Parameter 2 used to set the ice
making time. Short press the set
button will change the 2xx from 200 to
209, see ice making time table.
long press mode button,
release and then short
press mode button 1 time
SMG: show OFF for 10
seconds and then show
2xx->3xx
Parameter 3 used to set the harvest
time. Short press the set button will
change the 3xx from 300 to 309, see
harvest time table.
long press mode button,
release and then short
press mode button 2 time
SMG: show OFF for 10
seconds and then show
2xx->3xx->4xx
Parameter 4 used to set the pre-chill
time. Short press the set button will
change the 4xx from 400 to 490, see
pre-chill time table.
long press mode button,
release and then short
press mode button 3 time
SMG: show OFF for 10
seconds and then show
2xx->3xx->4xx->5xx
Parameter 5 used to set the gap
between 2 self-clean procedures.
Short press set button can change the
5xx from 500 to 590, see self-clean
frequency table.
long press mode button,
release and then short
press mode button 4 time
SMG: show OFF for 10
seconds and then show
2xx->3xx->4xx->5xx->6xx
Parameter 6 used to set the maximum
lack-of-water alarm time. Short press
set button can change the 6xx from
600 to 609, see maximum lack-of-
water table.
long press mode button,
release and then short
press mode button 5 time
SMG: show OFF for 10
seconds and then show
2xx->3xx->4xx->5xx-
>6xx->7xx
Parameter 7 is used to set the
maximum water inlet time. Short press
set button can change the 7xx from
700 to 709, see maximum water inlet
table.
long press mode button,
release and then short
press mode button 6 time
SMG: show OFF for 10
seconds and then show
2xx->3xx->4xx->5xx-
>6xx->7xx->8xx
Parameter 8 is used to set the ice
making lapse time. Short press set
button can change the 8xx from 800 to
809, see ice making lapse table.
long press mode button,
release and then short
press mode button 7 time
SMG: show OFF for 10
seconds and then show
2xx->3xx->4xx->5xx-
>6xx->7xx->8xx->9xx
Parameter 9 is used to set the
maximum condenser temperature.
Short press set button can change the
9xx from 900 to 909, see maximum
condenser temperature table.
long press mode button,
release and then short
press mode button 8 time
SMG: show OFF for 10
seconds and then show
2xx->3xx->4xx->5xx-
Parameter P is used to set the water
discharge frequency. Short press set
button can change the Pxx from P00 to