background image

Registration applies to the Boulder, Colorado 

PARTICLE MEASURING SYSTEMS HEADQUARTERS
5475 Airport Blvd., Boulder, CO 80301, USA
(303) 443-7100 1-800-238-1801 FAX: (303) 449-6870
Instrument Service & Support: 1-800-557-6363
Customer Response Center: 1-877-475-3317

PARTICLE MEASURING SYSTEMS EUROPE
Tel: +44 (0)1684-581000 FAX: +44 (0)1684-560337

PARTICLE MEASURING SYSTEMS ASIA PACIFIC
Tel: (65) 8460-500 FAX: (65) 8460-700

PARTICLE MEASURING SYSTEMS, JAPAN

Tel:  (81) 3-5298-8175  Fax:  (81) 3-3255-8155

PARTICLE MEASURING SYSTEMS, CHINA
Tel:  (86) 21-6113-3688 Ext. 751 Fax: (86) 21-6113-3683

PARTICLE MEASURING SYSTEMS, MEXICO
Tel: 52 55 22 71 51 06

PARTICLE MEASURING SYSTEMS , PUERTO RICO
Tel: 787-380-5468 or 787-380-5446

www.pmeasuring.com
[email protected]

HandiLaz®

Operator’s Manual

P/N M10255 Rev E

Содержание HandiLaz

Страница 1: ...el 44 0 1684 581000 FAX 44 0 1684 560337 PARTICLE MEASURING SYSTEMS ASIA PACIFIC Tel 65 8460 500 FAX 65 8460 700 PARTICLE MEASURING SYSTEMS JAPAN Tel 81 3 5298 8175 Fax 81 3 3255 8155 PARTICLE MEASURI...

Страница 2: ...without the express written permission of Particle Measuring Systems Inc Particle Measuring Systems may have patents or pending patent applications trademarks copyrights or other intellectual propert...

Страница 3: ...ring Technique Great Britain Distributor s Address Unit B1 South Willow End Park Danemoor Malvern WR14 1XZ Worchestershire WR13 6NN United Kingdom Distributor s Telephone FAX 011 44 1684 312950 011 44...

Страница 4: ...ION A CAUTION in the text is used to highlight an item that if not done or incorrectly done could damage the instrument and or any materials or devices affected by the instrument WARNING A WARNING in...

Страница 5: ...1 Keypad 4 1 Starting the HandiLaz 4 2 Battery Charge Indicator 4 2 Temperature and Humidity Sensor 4 3 Time Display 4 3 Display Contrast 4 3 Main Menu 4 3 Measure 4 4 Sampling Cycle Progress Screens...

Страница 6: ...oad and transfer 5 4 Zero count Filter Option 5 4 Battery Charger and Spare Battery Pack Option 5 4 Humidity and Temperature Sensor Option 5 5 Carry Case Option 5 5 Chapter 6 Troubleshooting 6 1 Chapt...

Страница 7: ...vii List of Figures Front and Side View 1 2 Battery Pack Connection 1 3 Rear View 1 4 Keypad Layout 4 1...

Страница 8: ...viii List of Figures This page is intentionally left blank...

Страница 9: ...handling and cleaning It operates from its own internal battery source as well as the external power supply unit which rapidly re charges the battery pack Features Small and can be carried comfortabl...

Страница 10: ...re designed to be easily used and cleaned Sides The right side includes the DC power jack and RS 232 connection to an optional printer or an external PC requires the optional CountWin software Top The...

Страница 11: ...nlet nozzle The protective cap for the inlet nozzle should be replaced when the HandiLaz is not in use CAUTION Only the battery pack supplied with the HandiLaz may be used use of any other battery pac...

Страница 12: ...is the product identification and serial label The third label space is intended for customer use and is left blank Tilt Stand The built in tilt stand supports the instrument for tabletop operation I...

Страница 13: ...volume 115 10 0 5 m Number of size channels 4 Channel thresholds 0 3 m 0 5 m 1 0 m and 5 0 m Environmental sensors Temperature and humidity probe optional Vaisala type 0 to 50 C 20 95 R H Communicati...

Страница 14: ...Internal batteries approximately 3 hours 15 min per charge in measurement mode Battery recharge time Using the internal charger Using the optional Rapid external battery charger 2 hours 1 hour Externa...

Страница 15: ...y the shipper and Particle Measuring Systems and repackage the unit in the original packing materials 3 If your shipment is undamaged store the packing materials It is important to store packing mater...

Страница 16: ...diLaz Operator s Manual Chapter 2 Unpacking External battery charger Power supply AC to DC converter AC power cord two Spare battery Humidity temperature sensor CountWin software PC cable Calibration...

Страница 17: ...ng instrument However severe or repeated shocks could have a long term effect on measurement accuracy instrument reliability Gross contamination HandiLaz is a sensitive environmental monitor Avoid exp...

Страница 18: ...icator on page 4 2 If the HandiLaz will be stored for longer than one month it is recommended that the battery pack be discharged by running the HandiLaz on battery power alone until it stops This wil...

Страница 19: ...troduces you to the user interface which is comprised of the keypad and the LCD display It also describes how to perform basic functions Keypad The unit s configuration and operation is controlled by...

Страница 20: ...creen will be displayed NOTE Temperature and humidity are only displayed when the optional temperature humidity probe is installed Battery Charge Indicator Small squares at the bottom of the display i...

Страница 21: ...reference To adjust the display contrast 1 Press and hold down the button 2 While holding down the button press either the or button The button will cause the contrast to increase until the display is...

Страница 22: ...fix the values To start a function menu such as Measure press Measure Entering this menu starts the measurement process which has its own set of sub menus The unit will first purge the optical chambe...

Страница 23: ...ge time this will be shown Otherwise the active measurement screens will be displayed immediately Active Measurement Screens There are four Active Measurement screens Count1 Count2 Sensors Status They...

Страница 24: ...t still beginning with N Df Absolute Differential Counts Count2 screen Identical to Count1 except that it displays the counts in the 5 0 m channel instead of the 1 0 m channel 0 3 56013 0 5 7370 5 0 1...

Страница 25: ...displayed in degrees Centigrade or Fahrenheit 3 Press the button to save your setting Status screen displays the time location Id Number the sample Number and number of samples taken the percentage of...

Страница 26: ...up sample to purge air This happens once per sample Delay Time This happens at the beginning of a series of samples Interval Time This is the time between samples within a group Number of Samples Geig...

Страница 27: ...oup measurement Yes Auto Increment No To set the location ID 1 From the MENU level press the or buttons until the Location Setup menu option appears 2 Press the button to activate the Location Setup m...

Страница 28: ...3 Press the button to save your setting and return to the Location Setup navigation level Review Data This menu causes the results held in internal memory to be displayed The data is scrolled into vi...

Страница 29: ...lears sample results from internal memory clears data collected To reset memory From the Reset Memory display press the Yes key Clock This has four sub menus Time Day Month Year To set Time Day Month...

Страница 30: ...Toggle Beep This menu allows the user to enable or disable a tone beep when a membrane key is pressed To enable a tone when a key is pressed From the Toggle Beep menu press the key To disable a tone...

Страница 31: ...rticle Measuring Systems PMS part PR20 Setting the DIP Switches on the HandiLaz External Printer Three sets of DIP switches each containing eight switches 24 total which identify the communication lan...

Страница 32: ...ial 2 ON Printing Speed High 3 ON Auto Loading ON 4 OFF Auto LF OFF 5 ON Setting Command Enable 6 OFF Printing 7 ON Density 8 ON 100 Dip SW 2 1 ON Printing Columns 40 2 ON User Font Back Up ON 3 ON Ch...

Страница 33: ...O 14644 BS5295 and Federal Standard 209E classifications on suitable data sets from the particle counter This occurs automatically upon reading the data CountWin can automatically export the results i...

Страница 34: ...its function as a zero count filter Battery Charger and Spare Battery Pack Option The external battery charger will fully charge a HandiLaz battery pack in one hour from a discharged state It enables...

Страница 35: ...the HandiLaz connection 2 Push the probe straight toward the HandiLaz chassis until the sensor snaps into place To remove the probe 1 Retract the sleeve on the bottom of the humidity temperature sens...

Страница 36: ...Page 5 6 HandiLaz Operator s Manual Chapter 5 Using Optional Accessories This page is intentionally left blank...

Страница 37: ...level Keypad does not respond Processing lock up Cycle power Turn unit off Wait 10 seconds and turn back on Ensure connection to any PC has followed the recommendations in the CountWin section Pump e...

Страница 38: ...Page 6 2 HandiLaz Operator s Manual Chapter 6 Troubleshooting This page is intentionally left blank...

Страница 39: ...mild soap and water solution and a soft lint free cloth The HandiLaz has been designed to withstand application of harsh solvents such as ethanol Care should be taken to avoid ingress of liquids of a...

Страница 40: ...Page 7 2 HandiLaz Operator s Manual Chapter 7 Maintenance This page is intentionally left blank...

Страница 41: ...rt Number PC cable CD31 External printer PR37 Carry case MI503 Spare battery pack AE2100 External battery charger AE2135 CountWin software FW000061 Zero count filter FL03 Printer paper PR20 Humidity t...

Страница 42: ...Page A 2 HandiLaz Operator s Manual Appendix A Options and Accessories This page is intentionally left blank...

Страница 43: ...sques d exposition aux radiations laser WARNUNG Das Gerat ist ein Laser der Klasse 1 Werden Einstellungen vorgenommen oder Verfahren eingesetzt die nicht in dieser Bedienungsanleitung beschrieben sind...

Страница 44: ...the equipment is as follows Symboles de risque Des symboles repr sentant les risques sont plac s sur l appareil Leur signification est la suivante Symbol Nature of Hazard Attention consult accompanyi...

Страница 45: ...ben folgende Bedeutungen Simboli di pericolo Il significato dei simboli di pericolo che appaiono sugli strumenti il seguente Symbol Gefahrenart Achtung In den beiliegenden Unterlagen nachschlagen Acht...

Страница 46: ...or s Manual Appendix B International Precautions Simbolos de peligro Los simbolos de peligro que aparecen en el equipo significan S mbolo Naturaleza del Peligro Atenci n consultar los documentos adjun...

Страница 47: ...tWin Installing 5 3 D Data download and transfer 5 4 Data Review 4 10 DIP Switches on the HandiLaz External Print er Setting the 5 1 Display Contrast 4 3 Display Time 4 3 download and transfer Data 5...

Страница 48: ...est 4 11 Sensor Option Humidity and Temperature 5 5 Sensor Temperature and Humidity 4 3 Setting the DIP Switches on the HandiLaz Ex ternal Printer 5 1 Setup Comms 4 10 Setup Installation and 3 1 Setup...

Отзывы: