2. Electrical Requirements
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked “Acceptable
for Fan Support of 22.7kg. (50 lbs.) or less”, and use
screws supplied with outlet box. Most outlet boxes
commonly used for support of light fixtures are
not acceptable for fan support and may need to be
replaced. Consult a qualified electrician if in doubt.
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box or circuit breaker panel before
wiring. All wiring must be in accordance with National
and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
WARNING
!
To avoid fire or shock, follow all wiring instructions
carefully.
Any electrical work not described in these
instructions should be done or approved by a licensed
electrician.
WARNING
!
Your new Ceiling Fan will require a Grounded Electrical
Supply Line of 120 Volts AC, 60 Hz, 15 Amp Circuit.
The Outlet Box must be securely anchored and capable
of withstanding a load of at least 50 Pounds.
If your Fan is to replace an Existing Ceiling Light
Fixture, turn Electricity OFF at the Main Fuse Box
or Circuit Breaker Panel at this time and remove the
Existing Light Fixture.
1. Unpacking Instructions
(Continued)
THESE FAN MODELS ARE SUITABLE FOR WET LOCATIONS
SUCH AS PORCHES, PATIOS, AND DECKS.
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One Phillips Head Screwdriver
One Stepladder
One 1/4” Blade Screwdriver
One Wire Stripper
Materials
Wiring outlet box and box connectors must be of type
required by the local code. The minimum wire would be
a 3-conductor (2-wire with ground) of following size:
Before assembling your ceiling fan, refer to section
on proper method of wiring your fan (page 12).
If you feel you do not have enough wiring knowledge
or experience, have your fan installed by a licensed
electrician.
WARNING
!
Installed Wire Length
Wire Size A.W.G.
Up to 50 ft.
14
50-100 ft.
12
1.2
Remove the Fan Motor Assembly from the protective
plastic bag. Place the Fan Motor Assembly onto the
upper foam pad with the Bottom of the Fan Motor
Assembly facing up.
The upper foam pad serves as a holder for the Fan
during the first stages of assembly.