Fire Place Insert Safe Clearances
Minimum clearances to combustible materials:
A
Side Wall to front side of Unit
200mm
B
Mantel to front top of Unit
325mm (Requires 290mm to allow hopper lid to fully open)
C
Top Rear of Unit
0mm
D
Side Rear of Unit
25mm
E
Rear of Unit
200mm
F
Floor Protector
150mm
G
Depth
450mm
H
Height
605mm
Notes: 1.
Other dimensions illustrated are for installation purposes.
2.
Ensure single skin flue has 75mm safe clearance to combustibles.
3.
Clearances shown in the side view below are minimum clearances, it is suggested that for ease of
maintenance, clearances of around 75mm or greater should be achieved where possible
Standard Surround is 1000mm