Inverter Usage Guide
Overview of buttons
Inputs
LCD Display
Outputs
Enter Key &
Scroll Key
Escape Key
How to change Barrier speed
1.
The display will show “
”
2.
Press the
ENT
Dial button
3.
Scroll the dial until
CONF
is shown on the display
4.
Press the
ENT
dial
5.
Scroll the dial until
LSP
is shown on the display
6.
Press the
ENT
dial
7.
The current speed is then shown Example:
32
8.
Now use the scroll dial
to set the desired speed you require
*
9.
Note
if this is increased/decreased considerably then the
ACC
and the
DEC
will also need to be adjusted to suit. For any
advice please contact the service department.
10.
Press the
ESC
button until
RDY
is shown in the display to exit
the menu.
ACC
is set to “6” by default this may be increased
DEC
is set to “2” by default this
may be increased
RDY
Please be aware limit switch strikers may have to be moved!!