![background image](http://html1.mh-extra.com/html/parker/pneudri-maxi/pneudri-maxi_user-manual_3924391017.webp)
i.e.
ITEMFILE: DHPNDRL1V3_5.NOD
becomes
ITEMFILE: DHPNDRL1V3_3.NOD
or
ITEMFILE: R1DHPNEU_V01.nod
Make this change to all dryers on the network. Save this file.
Returning to the "Station configuration/selection" window select "DRYER
STATION" and click "Set current station" then "Save on exit" then "Exit".
This will return to the main "Multi485" window where the message "Network
conversations are enabled" should be displayed.
Open Connections [topics]:
The number of nodes communicating via the ANI is displayed.
Current station:
The name of the current station file is displayed. The station file is selected
via the “Stations” drop down menu.
Messages received:
The number of messages received during the current running of the
<multi485.exe> file is displayed.
Open advise loops:
An advise loop is opened when the Adv command is entered in front of
certain DDE text strings. In these instances the node controller will automatically
advise the DDE server when that item has changed value or state.
Number of requests:
The number of requests for information sent by the DDE server during the
current running of the <multi485.exe> file is displayed.
Failed requests:
The number of failed requests for information sent by the DDE server during the
current running of the <multi485.exe> file is displayed. If the DDE server
continually returns failed requests, the problem is likely to be power supply (no
power to the ANI or the node) or wiring (break in the cable) related.
15