18
PHD
Inputs
A typical active-high digital input connection is shown below:
Internal to product
Active High
Digital Input
Battery
Application Switch
Figure 8: Active high digital input
3.3.3. PHD50/PHD70 frequency input capabilities
The PHD50 and PHD70 have 2 frequency inputs. These inputs are also
configurable as digital inputs. The frequency inputs are ideal for use with hall-
effect type sensors.
The following table provides specifications for the frequency inputs:
Frequency Input Specifications
Item
MIN
NOM
MAX
UNIT
Input range
0
5
32
V
Negative threshold
1.545
V
Positive threshold
4.008
V
Input capacitance at pin
0.1
µF
Over-voltage
36
V
Frequency accuracy
3
%
Frequency range (see note)
0
1500
Hz
Pull-up resistor to min 4.3V, max 5V
1.2
kΩ
Pull-down resistor
26.2
kΩ
Note:
Electrically signals to 0 are possible, but the software will limit the minimum
measurable frequency