56
File components
Appendix A
Instruction book, PHD API Reference
Message
Object
message
Parent:
controllerApplication
Data
Attributes
Type
Required
Description
pgn
number
Yes
The J1939 Parameter Group
Number in decimal format. Valid
values are 0 – 65535.
ignoreSourceAddress
boolean
Yes
A Boolean value indicating
whether the source address of the
messages should be ignored. If set
to ‘true’, sourceAddress property
must be present.
sourceAddress
number
No
The J1939 source address of the
message. If ignoreSourceAddress
is set to ‘false’, the message is
filtered on source address as well
as PGN
notifyStale
boolean
Yes, for receive
A Boolean value indicating
whether the subscriber will be
notified if the message becomes
stale. Requires
staleTimeoutPeriod. Only valid
for receive type messages.
length
number
Yes
The length pf the address in bytes
rateLimit
number
No
Sets the rate at which new values
for the receive message are
published. Setting the value to 0
or not specifying this attribute
removes the rate limit. Specified
in milliseconds.
staleTimeoutPeriod
number
No
Sets the stale timeout period for
the message. The subscriber will
be notified if the specified period
of time elapses following the last
valid receipt of the message.
Required if notifyStale is set to
‘true’. Specified in milliseconds.
Содержание PHD28
Страница 1: ...Parker Hannifin Display PHD User Guide UG PHD 1040001 201707 010...
Страница 52: ...44 PHD Mounting the PHD 9 1 2 PHD50 Figure 18 PHD50 dimensions mm...
Страница 53: ...User Guide 45 Mounting the PHD 9 1 3 PHD70 Figure 19 PHD70 dimensions mm...
Страница 58: ...Parker Hannifin Display PHD User Guide HY33 5021 IB US...
Страница 59: ...PHD Network Interface Configuration Publ no HY33 5021 M1 UK Edition 2017 02 02...
Страница 75: ...PHD API Reference Publ no HY33 5021 M2 UK Edition 2017 02 13...