Hydraulic and Electrohydraulic Actuators
HAS Series Analog Drives Manual
99
Parker Hannifin Corporation
Cylinder Division
Des Plaines, Illinois USA
www.parker.com
/cylinder
Catalog HY08-4005-M3
WARNING:
This product can expose you to chemicals including
Lead and Lead Compounds
which are known to the State of
California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
PROP 65 WARNING
Trip Table
66551111
K
Keeyyppaadd
D
Diissppllaayy
66990011
K
Keeyyppaadd
D
Diissppllaayy
D
Deessccrriippttiioonn
P
Poossssiibbllee R
Reeaassoonn ffoorr TTrriipp
ATN 3
NOT AT SPEED
♦
The motor was unable to reach the required speed to
carry out the Autotune. Possible reasons
include: motor shaft not free to turn; the
motor data is incorrect
ATN4
MAG CURRENT
FAIL
♦
It was not possible to find a suitable value of
magneti
z
ing current to achieve the required
operating condition for the motor. Check the
motor data is correct, especially nameplate
rpm and motor volts. Also check that the motor
is correctly rated for the drive.
ATN5
NEGATIVE SLIP F
♦
Autotune has calculated a negative slip frequency,
which is not valid. Nameplate rpm may have
been set to a value higher than the base speed
of the motor. Check nameplate rpm, base
frequency, and pole pairs are correct.
ATN6
TR TOO LARGE
♦
The calculated value of rotor time constant is too
large. Check the value of nameplate rpm.
ATN7
TR TOO SMALL
♦
The calculated value of rotor time constant is too
small. Check the value of nameplate rpm.