Catalog HY08-4005-M3
112
Hydraulic and Electrohydraulic Actuators
HAS Series Analog Drives Manual
Parker Hannifin Corporation
Cylinder Division
Des Plaines, Illinois USA
113
www.parker.com
/cylinder
www.parker.com
/cylinder
Program Blocks
DWN
CHK
APP
EDIT
LOC
SIZE A DWG. NO.
ISSUE
SCALE
SHEET
BBESCH 03/21/19
Hybrid Actuator Series HAS 500
099176***00-A/1/099~00-BASE.316
RF0991760***-00A
1 OF 2
Parker Cylinder Divison-
Des Plaines, IL 60016
(847) 298-2400 www.parker.com/cylinder
HAS Analog Discrete Programmed Drive
NEVER do a Full Install !!
C G or INSTALL ONLY
x=y
x
y
0
4
IEQ
I/O CONFIGURATION:ANALOG INPUT 4 TYPE
HAS Control :Stop on PSI (bit)
ENABLE
STATE
X15-01
E
F
Enable
SYSTEM
CONTROL
1
System
HAS Control :Stop On Position (Bit)
HAS Control :Invert LW State
VIEW LEVEL
STARTUP SCREEN
PASSWORD
COMMS PORT MODE
CONFIG NAME
BASIC
0
0x0011
AUTOMATIC
ACCESS CONTROL
(SHT 2) Reservoir Temp.1:Trip
HAS Control :Speed V1
AND
HAS Control :Speed V2
Invert LW State
Invert Direction
Pump Displacement (CC)
Speed V1
HAS Mode
Speed V2
Stop On Position (Bit)
Position High Limit
Stop on PSI (bit)
Stop PSI CW (Value)
Position Scaled
Position Low Limit
Stop PSI CCW (value)
Stop PSI CW Time (Value)
Stop PSI CCW Time (Value)
Torque
JOG
REVERSE
Cap End of Stroke Switch State
Head End of Switch State
Jog Speed Out
Run Speed Out
Max Motor RPM
Stopped on PSI CW
Stopped on PSI CCW
Calulated PSI
Analog Input 4 type
Mode 4
1
2
3
50
0
10
F
10
F
1000
0
1
1000
3
3
0
HAS Control
Motor Control:PSI Stop CW Val
Motor Control:End of Stroke SW NC
(SHT 2) Hours X 0.1:Hours
Motor Control:V1 Speed Out
Motor Control:PSI Stop CCW Val
Heat Exchnager Control :Enable (SHT 2)
HAS Control :Pump Displacement (CC)
(SHT 2) Reservoir Temp.1:Temp Sensor Fault
Motor Control:V2 Speed Out
Motor Control:JOG
Motor Control:CCW Stop Time
Heat Exchnager Control :Cooler On Temp (SHT 2)
(SHT 2) Has Temp Int:OUTPUT
Motor Control:Position stop high
Hours of Operation:RPM (SHT 2)
HAS Control :Stop PSI CCW (value)
HAS Control :HAS Mode
(SHT 2) Positon (in):OUTPUT
Motor Control:TORQUE
Motor Control:Pump Displacement
ANALOG INPUT 1 TYPE
ANALOG INPUT 2 TYPE
ANALOG INPUT 3 TYPE
ANALOG INPUT 4 TYPE
ANALOG OUTPUT 1 TYPE
ANALOG OUTPUT 2 TYPE
0..+10 V
0..+10 V
0..20 mA
0..+10 V
-10..+10 V
-10..+10 V
I/O CONFIGURATION
Hours X 0.1:Reset Hour (SHT 2)
Hours of Operation:Running (SHT 2)
HAS Control :Stop PSI CW (Value)
HAS Control :REVERSE
HAS Control :Invert Direction
(SHT 2) Positon (in):OUTPUT
VPS.6:INPUT (SHT 2)
HAS Control :Stop PSI CCW Time (Value)
HAS Control :Position Low Limit
HAS Control :Jog Speed Out
HAS Control :JOG
HAS Control :Calulated PSI
DRIVE NAME
CONTROL MODE
SUPPLY VOLTAGE
FBK FITTED
SLOT A FITTED
SLOT B FITTED
890 DRIVE
PMAC
380V TO 480V
DRIVE CONFIG
(SHT 2) Hours X 0.1:Change Oil
Motor Control:HAS Mode
Motor Control:CW Stop Time
ENABLE
JOG
REVERSE
Jog Speed
Mode 4 Speed Input
Run
NOT-STOP
Force Limit
Reset Position to Zero
Max Motor RPM
Res Temp Trip
Temp_2_Display
Hours
Oil Change required
Mode 4 Min RPM
Position Actual
PSI Actual
Temp Sensor Fault
SPEED
TORQUE
RUNNING
ZERO SPEED
HEALTHY
Resolver Counts
Motor RPM
Motor Amps
V1 Speed Out
V2 Speed Out
Pump Displacement
End of Stroke SW NC
HAS Mode
Invert Direction
Position stop high
Position Stop Low
Stop on PSI
Stop On Position
CCW Stop Time
CW Stop Time
Reset Hours
PSI Stop CW Val
PSI Stop CCW Val
Position Value at 100%
Cooling ON Value (F)
Cooling Loop On Command
TRUE
FALSE
FALSE
0%
0
FALSE
TRUE
275 %
FALSE
4000
F
0
0
FALSE
500 RPM
0
0.76 %
FALSE
Motor Control
HAS Control :Run Speed Out
HAS Control :Position High Limit
Motor Control:REVERSE
Motor Control:Invert Direction
HAS Control :Torque
HAS Control :Mode 4
HAS Control :Max Motor RPM
Motor Control:PSI Actual
Motor Control:Position Stop Low
Motor Control:Jog Speed
HAS Control :Analog Input 4 type
Motor Control:Stop on PSI
Motor Control:Mode 4 Speed Input
HAS Control :Stop PSI CW Time (Value)
Motor Control:Stop On Position
Motor Control:Max Motor RPM
IEQ:x