Hydraulic and Electrohydraulic Actuators
HAS Series Analog Drives Manual
95
Parker Hannifin Corporation
Cylinder Division
Des Plaines, Illinois USA
www.parker.com
/cylinder
Catalog HY08-4005-M3
WARNING:
This product can expose you to chemicals including
Lead and Lead Compounds
which are known to the State of
California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
PROP 65 WARNING
Trip Table
66551111
K
Keeyyppaadd
D
Diissppllaayy
66990011
K
Keeyyppaadd
D
Diissppllaayy
D
Deessccrriippttiioonn
P
Poossssiibbllee R
Reeaassoonn ffoorr TTrriipp
DISP
OP STATION
Keypad has been
disconnected from drive whilst
drive is running in local control
♦
Keypad accidentally disconnected from drive
SCI
COMMS BREAK
♦
COMMS BREAK parameter set to True (refer to I/O
TRIPS menu at level 3)
CNTC
CONTACTOR FBK
♦
The CONTACTOR CLOSED input in the
SEQUENCING LOGIC function block remained
FALSE after a run command was issued
SPD
SPEED FEEDBACK
♦
SPEED ERROR > 50.00% for 10 seconds
AOT
AMBIENT TEMP
♦
The ambient temperature in the drive is too high