Safe Torque Off
EExxaam
mpplleess ooff w
wiirriinngg ttoo XX1111//0055 aanndd XX1111//0066.
Active high output:
Active low output:
The load is energi
z
ed and X11/05 is high
when STO is in the intended safe STO
state.
The load is energi
z
ed and X11/06 is low
when STO is in the intended safe STO
state.
X11/06
X14/03
24VDC
X11/05
X14/04
890STO
LOAD
X11/06
X14/03
24VDC
X11/05
X14/04
890STO
LOAD
0V
0V
Hybrid Actuation System
Cylinders SSeerriieess H
HAASS 550000
Catalog HY08-
SSaaffee TToorrqquuee O
Offff
W
WAARRN
NIIN
NG
G:: This product can expose you to chemicals including LLeeaadd aanndd LLeeaadd C
Coom
mppoouunnddss which are known to the State of
PPR
RO
OPP 6655 W
WAAR
RN
NIIN
NG
G
California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
PPaarrkkeerr H
Haannnniiffiinn C
Coorrppoorraattiioonn
Cylinder Division
Des Plaines, Illinois
56
w
ww
ww
w..ppaarrkkeerr..ccoom
m/
cylinder
•
The examples show the use of the 24V supply provided on X14/03 (+24V) and X14/04 (0V)
as source of power to a load. Alternatively an external 24V supply could be used.
Note: If a drive is powered from 24V only, i.e., 24V is applied to terminals X13/01 or X13/02
and the 3 phase power is off, the STO user output will still reflect the status of the two STO
user inputs.
SSTTO
O TTeecchhnniiccaall SSppeecciiffiiccaattiioonn
IInnppuuttss SSppeecciiffiiccaattiioonn
STO A Input and STO B Input comply with IEC61131-2. Note: inputs do not have hysteresis.
Recommended input voltage for low level:
0V to +5V
Recommended input voltage for high level:
Typical input threshold voltage: Absolute
maximum input voltage: Typical input
current @ 24V Indeterminate input range:
Fault detection time
3
:
+
21.6V to +26.4V
+
10.5V
-30V to +30V
9mA
+5V to +15V. Function is undefined.
2.3sec typical;
< 1.6sec will not generate a fault
>
3.0sec will generate a
fault.
STO Technical Specification
Inputs Specification