Hydraulic and Electrohydraulic Actuators
HAS Series Analog Drives Manual
57
Parker Hannifin Corporation
Cylinder Division
Des Plaines, Illinois USA
www.parker.com
/cylinder
Catalog HY08-4005-M3
WARNING:
This product can expose you to chemicals including
Lead and Lead Compounds
which are known to the State of
California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
PROP 65 WARNING
Safe Torque Off
Hybrid Actuation System
Cylinders S
Seerriieess H
HA
AS
S 550000
Catalog HY08-
S
Saaffee TToorrqquuee O
Offff
W
WAAR
RN
NIIN
NG
G:: This product can expose you to chemicals including LLeeaadd aanndd LLeeaadd C
Coom
mppoouunnddss which are known to the State of
California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
P
PR
RO
OP
P 6655 W
WA
AR
RN
NIIN
NG
G
P
Paarrkkeerr H
Haannnniiffiinn C
Coorrppoorraattiioonn
Cylinder Division
Des Plaines, Illinois
57
w
ww
ww
w..ppaarrkkeerr..ccoom
m/
cylinder
•
O
Ouuttppuutt S
Sppeecciiffiiccaattiioonn
OFF state:
Maximum
applied
voltage:
Reverse
voltage
protection:
Leakage current:
ON state:
Maximum output current:
Overcurrent protection: Voltage
drop X11/06 to X11/05:
+30V (X11/06 relative to X11/05)
Up to -30V X11/06 relative to X11/05 Less
than 1mA when output is off.
150mA
Included, implemented by a resettable
fuse. Less than 2.5V, see below.
W
WA
AR
RN
NIIN
NG
G
WIRED CONNECTIONS TO TERMINALS
X11/01, X11/03, X11/05 AND X11/06
MUST BE LESS THAN 25 METRES IN
LENGTH AND REMAIN WITHIN THE
CUBICLE OR DRIVE ENCLOSURE.
PARKER HANNIFIN MANUFACTURING
IS NOT LIABLE FOR ANY
CONSEQUENCES IF EITHERCONDITION
IS NOT MET.
0
1
0.
5
2
1.
5
TTyyppiiccaall U
Usseerr O
Ouuttppuutt VVoollttaaggee D
Drroopp vvss C
Cuurrrreenntt
2.5
0
20
40
60
80 100 120
140
160
O
Ouuttppuutt ccuurrrreenntt ((m
mA
A))
OO
uutt
ppuu
tt VV
ooll
ttaa
ggee
DD
rroo
pp
S
STTO
O S
Sttaattuuss
IInnppuutt A
A
IInnppuutt B
B
O
Ouuttppuutt
XX1111//0011
XX1111//0033
XX1111//0055,, XX1111//0066
S
STTO
O A
Accttiivvee
0 V
0V
Drive cannot start or supply power to its motor. STO trip
reported if drive is running or drive start is attempted. This is
the intended safe state of the product with correct
dual-channel operation.
ON
24V
0V
0V
24V
S
STTO
O IInnaaccttiivvee
24V
24V
Drive is enabled to run under software control. The drive can
supply power to its motor.
OFF
S
STTO
O
O
Ovveerrvviieew
w
D
Drriivvee FFuunnccttiioonn
A
Abbnnoorrm
maall oonnee--
cchhaannnneell
ooppeerraattiioonn
ddeetteeccttiioonn
Drive cannot start or supply power to its motor. STO trip
reported if drive is running or drive start is attempted. If either
of these conditions persists for more than 3.0 seconds (the
maximum fault detection time), the STO function will lock into
a fault state. The drive cannot start until the fault is rectified,
all power is removed and reapplied (both mains and any
auxiliary 24V dc power). This is single channel operation and
thus deemed not as intended for category 3 / PLe / SIL3
structure implementation.
OFF
TTrruutthh TTaabbllee
Output Specification
Truth Table