MA-K17510-KW LinerSCAN manual ISSUE P.doc
Page 52 of 93
5.2.7 Operator Data Tab
The “Operator Data” (F4) screen is the location where the time of changes to engine parameters or
parts can be recorded. Explanation of each setting is as follows:
1. Cylinder. Select the cylinder which requires alteration
2. New Liner. Engine hours when a new liner was fitted
3. New Piston Fitted. Engine hours when new piston was fitted.
4. New Piston Rings. Engine hours when new piston rings were fitted
5. Clear Values in all boxes.
6. Update the cylinder log files once changes have been made.
7. TBN Measurement. Allows cylinder waste oil TBN measurements to be recorded with ppm wear values.
1
2
2
3
4
7
6
5